Chapter 3 - Commissioning
NOTE
Most parameters are changed to their new values only after reset (refer to
details). Once the basic parameters are configured, the unit should be reset in order to activate the
new configuration.
3.2.2

Configuration Tools

The CPEs include a Web Configuration Server, providing a web-based GUI for
local configuration and monitoring. The Web Configuration Server can be
accessed using a PC/Notebook with a web browser.
The CPE may be delivered with the operator's default settings already configured
in the FLASH memory. The only parameters that should be configured (if
necessary) are the end user's credentials (User Name and User Password).
3.2.3

Using the Web Configuration Server

To configure basic parameters:
Connect a PC/Notebook with a web browser to the Ethernet port of the CPE,
1
using a straight Ethernet cable.
Configure the PC's IP parameters to enable connectivity with the unit. The IP
2
address of the CPE for local management access is 192.168.254.251. The
Subnet Mask is 255.255.255.0. The recommended IP address for the PC is
192.168.254.250, as this is also the default TFTP Sever IP Address (required
for downloading SW versions and for downloading/uploading configuration
files).
Open a web browser, and connect to http://192.168.254.251. The "Enter the
3
Password" prompt is displayed. Enter the password and press the Enter key.
NOTE
The default password is "installer".
BreezeMAX PRO 5000 CPE
33
Configuring Basic Parameters