3 SPECIFICATIONS

3 SPECIFICATIONS
This section explains the MELSECNET/H board general specifications, performance
specifications.

3.1 General Specifications

This section explains the MELSECNET/H board general specifications.
Item
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Vibration resistance
Shock resistance
Operating atmosphere
i
t
1
Operating altitude
Installation location
2
Over-voltage category
3
Pollution rate
1: Do not use or store the board under pressure higher than the atmospheric pressure of altitude 0m.
Doing so may cause a malfunction.
2: This indicates the section of the power supply to which the equipment is assumed to be connected
between the public electrical power distribution network and the machinery within the premises. Category
II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage
withstand level for up to the rated voltage of 300 V is 2500 V.
3: This index indicates the degree to which conductive material is generated in terms of the environment in
which the equipment is used. Pollution level 2 is when only non-conductive pollution occurs. A temporary
conductivity caused by condensation must be expected occasionally.
3 - 1
Frequency
5 to 8.4 Hz
Compliant with
8.4 to 150 Hz
JIS B 3502 and
IEC 61131-2
Frequency
5 to 8.4 Hz
8.4 to 150 Hz
IEC 61131-2 (147 m/s
REMARK
General specifications both MELSECNET/H board and a personal computer must
be satisfied after installation.
Specifications
0 to 55 °C
-25 to 75 °C
5 to 95 % RH, non-condensing
Under intermittent vibration
Constant
Half
acceleration
amplitude
3.5 mm
2
9.8m/s
Under continuous vibration
Constant
Half
acceleration
amplitude
1.75 mm
2
4.9m/s
Compliant with JIS B 3502 and
2
, 3 times each in X, Y, and Z directions)
No corrosive gases
0 to 2000 m
Inside a control panel
II or less
2 or less
MELSEC
3
Sweep count
10 times each in
X, Y and Z
directions
Sweep count
3 - 1