12 APPLICATION FUNCTIONS

12.2.3 Startup

12 - 7
(1) Sending of data for one station per link scan (default)
The low-speed cyclic data for a maximum of one station is sent in one link scan
of the normal cyclic transmission.
[Setting method]
1)
Click ( ) "Transmit data of one station in 1 scan" to select.
POINT
The fastest link scan time in the low-speed cyclic transmission can be calculated by
the following equation:
LS
= LS
number of stations + LS
L
= LS
(number of stations + 1)
LS
: The fastest link scan time in the low-speed cyclic transmission
L
LS
: Normal link scan time
(2) Fixed term cycle interval setting
The low-speed cyclic data is sent in the link cycle of the designated time
frequency.
Valid setting frequency: 1 to 65535 s (18 h, 12 min and 15 s)
[Setting method]
1)
Click ( )"Fixed term cycle interval setting" to select.
2)
Set the time in seconds (the screen shows a value of 600).