Mitsubishi Electric SW0DNC-MNETH-B User Manual page 134

Melsecnet/hnetwork interface board
Table of Contents

Advertisement

11 PROGRAMMING
11
Device
Name
SB20
Module status
Baton pass status of
SB47
host
Data link status of
SB49
host
Baton pass status of
SB70
each station
Data link status of
SB74
each station
SW70
Baton pass status of
to
each station
73
(per station number)
SW74
Data link status of
to
each station
77
(per station number)
11 - 2
Assignment of link special relays (SB) and link special registers (SW) when multiple
boards are installed
Description
Indicates the communication status between
MELSECNET/H board and personal computer.
Indicates the baton pass status of the host.
It is in a status that the cyclic transmission and
transient transmission can be performed when it is
normal.
Indicates the data link status (cyclic transmission
status) of the host.
Indicates the baton pass status of each station
(including the host).
Reserved stations and stations having numbers
higher than the maximum station number are not
included.
This device turns off when SW70 to 73 are all "0".
Indicates the data link (cyclic transmission) status of
each station (including the host).
Reserved stations and stations having numbers
higher than the maximum stations number are not
included.
This device turns off when SW74 to 77 are all "0".
Stores the baton pass status of each station
(including the host).
b15 b14 b13 b12
to
to
SW70
16
15
14
13
SW71
32
31
30
29
to
SW72
48
47
46
45
to
SW73
64
63
62
61
to
Numbers 1 to 64 in the table denote station numbers.
Stores the data link (cyclic transmission) status of
each station. (Including the host)
b15 b14 b13 b12
to
to
16
15
14
13
SW74
to
32
31
30
29
SW75
48
47
46
45
to
SW76
64
63
62
61
to
SW77
Numbers 1 to 64 in the table denote station numbers.
Off (0)
Normal
Normal
(Data link enabled)
Data link being executed
(Executing cyclic
transmission)
All stations normal
All stations executing
data link
(All stations executing
cyclic transmission)
Baton pass normal
(including reserved
b4
b3
b2
b1
b0
stations during online
5
4
3
2
1
and stations having
21
20
19
18
17
numbers higher than the
37
36
35
34
33
maximum station
53
52
51
50
49
number)
Executing data link
(including reserved
b4
b3
b2
b1
b0
5
4
3
2
1
stations and stations
21
20
19
18
17
having numbers higher
37
36
35
34
33
than the maximum
53
52
51
50
49
station number)
MELSEC
Device status
On (1)
Abnormal
Abnormal
(Host disconnected)
Data link being stopped
(Set after refresh
completion)
One or more stations are
abnormal
One or more stations are
not executing data link
Baton pass abnormal
(including reserved
stations during offline
test and stations having
numbers higher than the
maximum station
number)
Station not executing
data link
11 - 2