6 PROCEDURE AND SETTINGS UP TO THE POINT OF OPERATION
6 - 15
(c) When connecting a coaxial cable, the following restrictions on the bending
radius must be observed.
Allowable bending radius
Cable type
3C – 2V
5C – 2V
5C – FB
(d)
Do not pull any of the connected coaxial cables.
This may cause a faulty contact and cable disconnection, or damage the
Q80BD-J71BR11.
(e)
In the coaxial bus type network system be sure to connect terminal
resistors in both end terminals in the network.
( f )
There is a possibility that of a white oxidation product forming on the type F
connector due to the use environment, but it does not occur on the portions
that are fitted together, so functionally, there will be no problem.
(g)
When attaching or detaching the coaxial cable to/from the module, make
sure to power off the personal computer.
Connector
r [mm (in.)]
A (mm (in.))
23 (0.91)
55 (2.17)
30 (1.18)
MELSEC
A
r
6 - 15