GE L60 Instruction Manual page 611

Line phase comparison system ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 45 of 59)
ADDR
REGISTER NAME
B88D
...Repeated for module number 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (16 modules)
B900
Configurable GOOSE Dataset Items for Reception
(32 items)
B920
...Repeated for module number 2
B940
...Repeated for module number 3
B960
...Repeated for module number 4
B980
...Repeated for module number 5
B9A0
...Repeated for module number 6
B9C0
...Repeated for module number 7
B9E0
...Repeated for module number 8
BA00
...Repeated for module number 9
BA20
...Repeated for module number 10
BA40
...Repeated for module number 11
BA60
...Repeated for module number 12
BA80
...Repeated for module number 13
BAA0
...Repeated for module number 14
BAC0
...Repeated for module number 15
BAE0
...Repeated for module number 16
Contact Inputs (Read/Write Setting) (96 modules)
BB00
Contact Input 1 Name
BB06
Contact Input 1 Events
BB07
Contact Input 1 Debounce Time
BB08
...Repeated for Contact Input 2
BB10
...Repeated for Contact Input 3
BB18
...Repeated for Contact Input 4
BB20
...Repeated for Contact Input 5
BB28
...Repeated for Contact Input 6
BB30
...Repeated for Contact Input 7
BB38
...Repeated for Contact Input 8
BB40
...Repeated for Contact Input 9
BB48
...Repeated for Contact Input 10
BB50
...Repeated for Contact Input 11
BB58
...Repeated for Contact Input 12
BB60
...Repeated for Contact Input 13
BB68
...Repeated for Contact Input 14
BB70
...Repeated for Contact Input 15
BB78
...Repeated for Contact Input 16
BB80
...Repeated for Contact Input 17
BB88
...Repeated for Contact Input 18
BB90
...Repeated for Contact Input 19
BB98
...Repeated for Contact Input 20
BBA0
...Repeated for Contact Input 21
BBA8
...Repeated for Contact Input 22
BBB0
...Repeated for Contact Input 23
BBB8
...Repeated for Contact Input 24
BBC0
...Repeated for Contact Input 25
BBC8
...Repeated for Contact Input 26
BBD0
...Repeated for Contact Input 27
BBD8
...Repeated for Contact Input 28
BBE0
...Repeated for Contact Input 29
BBE8
...Repeated for Contact Input 30
BBF0
...Repeated for Contact Input 31
BBF8
...Repeated for Contact Input 32
GE Multilin
RANGE
0 to 197
---
0 to 1
0 to 16
L60 Line Phase Comparison System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F233
---
---
F205
---
1
F102
ms
0.5
F001
DEFAULT
0 (None)
B
"Cont Ip 1"
0 (Disabled)
20
B-53

Advertisement

Table of Contents
loading

Table of Contents