GE L60 Instruction Manual page 573

Line phase comparison system ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 7 of 59)
ADDR
REGISTER NAME
2348
Fault 1 Prefault Phase C Current Angle
2349
Fault 1 Prefault Phase A Voltage Magnitude
234B
Fault 1 Prefault Phase A Voltage Angle
234C
Fault 1 Prefault Phase B Voltage Magnitude
234E
Fault 1 Prefault Phase B Voltage Angle
234F
Fault 1 Prefault Phase C Voltage Magnitude
2351
Fault 1 Prefault Phase C Voltage Angle
2352
Fault 1 Phase A Current Magnitude
2354
Fault 1 Phase A Current Angle
2355
Fault 1 Phase B Current Magnitude
2357
Fault 1 Phase B Current Angle
2358
Fault 1 Phase C Current Magnitude
235A
Fault 1 Phase C Current Angle
235B
Fault 1 Phase A Voltage Magnitude
235D
Fault 1 Phase A Voltage Angle
235E
Fault 1 Phase B Voltage Magnitude
2360
Fault 1 Phase B Voltage Angle
2361
Fault 1 Phase C Voltage Magnitude
2363
Fault 1 Phase C Voltage Angle
2364
Fault 1 Type
2365
Fault 1 Location based on Line length units (km or miles)
2366
...Repeated for Fault 2
238C
...Repeated for Fault 3
23B2
...Repeated for Fault 4
23D8
...Repeated for Fault 5
Synchrocheck Actuals (Read Only) (4 modules)
2400
Synchrocheck 1 Delta Voltage
2402
Synchrocheck 1 Delta Frequency
2403
Synchrocheck 1 Delta Phase
2404
...Repeated for Synchrocheck 2
2408
...Repeated for Synchrocheck 3
240C
...Repeated for Synchrocheck 4
Autoreclose Status (Read Only)
2410
Autoreclose 1 Count
Remote Double-Point Status Inputs (Read/Write Setting Registers) (5 modules)
2620
Remote Double-Point Status Input 1 Device
2621
Remote Double-Point Status Input 1 Item
2622
Remote Double-Point Status Input 1 Name
2628
Remote Double-Point Status Input 1 Events
2629
... Repeated for Double-Point Status Input 2
2632
... Repeated for Double-Point Status Input 3
263B
... Repeated for Double-Point Status Input 4
2644
... Repeated for Double-Point Status Input 5
IEC 61850 GGIO5 Configuration (Read/Write Setting Registers) (16 modules)
26B0
IEC 61850 GGIO5 uinteger Input 1 Operand
26B1
IEC 61850 GGIO5 uinteger Input 2 Operand
26B2
IEC 61850 GGIO5 uinteger Input 3 Operand
26B3
IEC 61850 GGIO5 uinteger Input 4 Operand
26B4
IEC 61850 GGIO5 uinteger Input 5 Operand
26B5
IEC 61850 GGIO5 uinteger Input 6 Operand
26B6
IEC 61850 GGIO5 uinteger Input 7 Operand
26B7
IEC 61850 GGIO5 uinteger Input 8 Operand
26B8
IEC 61850 GGIO5 uinteger Input 9 Operand
GE Multilin
RANGE
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 11
-3276.7 to 3276.7
-1000000000000 to
1000000000000
0 to 655.35
0 to 359.9
0 to 65535
1 to 32
0 to 64
1 to 64
0 to 1
---
---
---
---
---
---
---
---
---
L60 Line Phase Comparison System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
---
1
F148
---
0.1
F002
V
1
F060
Hz
0.01
F001
degrees
0.1
F001
---
1
F001
---
1
F001
---
1
F606
---
1
F205
"RemDPS Ip 1"
---
1
F102
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
DEFAULT
0
0
0
0
0
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (NA)
0
0
0
0
0
1
0 (None)
0 (Disabled)
0
0
0
0
0
0
0
0
0
B-15