GE L60 Instruction Manual page 589

Line phase comparison system ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 23 of 59)
ADDR
REGISTER NAME
Phase Comparison Negative Sequence Current Rate of Change (ROC) (Read/Write Grouped Setting)
6080
Negative Sequence di/dt FD Function
6081
Negative Sequence di/dt FDL Pickup
6082
Negative Sequence di/dt FDL Seal-In
6083
Negative Sequence di/dt FDH Pickup
6084
Negative Sequence di/dt FDH Seal-In
6085
Negative Sequence di/dt FDH Supv
6087
Negative Sequence di/dt FD Block
6089
Negative Sequence di/dt FD Target
608A
Negative Sequence di/dt FD Events
Phase Comparison Rate of Change of Positive-Sequence Current Settings (Read/Write Grouped Setting)
6092
Positive-Sequence Current Rate of Change (di/dt FD)
Function
6093
Positive-Sequence Current Rate of Change Low (di/dt FDL)
Pickup
6094
Positive-Sequence Current Rate of Change Low (di/dt FDL)
Seal-In
6095
Positive-Sequence Current Rate of Change High (di/dt
FDH) Pickup
6096
Positive-Sequence Current Rate of Change High (di/dt
FDH) Seal-In
6097
Positive-Sequence Current Rate of Change (di/dt FDH)
Supervision
6099
Positive-Sequence Current Rate of Change (di/dt FD)
Block
609B
Positive-Sequence Current Rate of Change (di/dt FD)
Events
609C
Positive-Sequence Current Rate of Change (di/dt FD)
Target
Phase Comparison Negative-Sequence Current Fault Detector (Read/Write Grouped Setting)
60A0
Negative-Sequence Current Fault Detector Function
60A1
Negative-Sequence Current Fault Detector Low Pickup
60A2
Negative-Sequence Current Fault Detector High Pickup
60A3
Negative-Sequence Current Fault Detector Block
60A5
Negative-Sequence Current Fault Detector Target
60A6
Negative-Sequence Current Fault Detector Events
Phase Comparison Positive-Sequence Current Fault Detector (Read/Write Grouped Setting)
60A8
Positive-Sequence Current Fault Detector Function
60A9
Positive-Sequence Current Fault Detector Low Pickup
60AA
Positive-Sequence Current Fault Detector High Pickup
60AB
Positive-Sequence Current Fault Detector Block
60AD
Positive-Sequence Current Fault Detector Target
60AE
Positive-Sequence Current Fault Detector Events
Phase Comparison Open Breaker Keying (Read/Write Grouped Setting)
60C0
Open Breaker Keying
60C1
Breaker 1 Auxiliary Contact
60C3
Breaker 1 Supervision Element
60C5
Breaker 2 Auxiliary Contact
60C7
Breaker 2 Supervision Element
60C9
Weak-Infeed Keying
60CB
Supervision Element
60CD
Infeed Pickup Delay
60CE
Infeed Reset Delay
60CF
Open Breaker Keying Pickup Delay
60D0
Open Breaker Keying Reset Delay
Phase Comparison Trip Scheme (Read/Write Grouped Setting)
60E0
87PC Function
GE Multilin
RANGE
0 to 1
0.01 to 5
0 to 10
0.01 to 5
0 to 10
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
0 to 1
0.01 to 5
0 to 10
0.01 to 5
0 to 10
0 to 4294967295
0 to 4294967295
0 to 1
0 to 2
0 to 1
0.02 to 5
0.05 to 15
0 to 4294967295
0 to 2
0 to 1
0 to 1
0.2 to 5
0.5 to 15
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 50
0 to 50
0 to 50
0 to 50
0 to 1
L60 Line Phase Comparison System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
pu
0.01
F001
s
0.001
F001
pu
0.01
F001
s
0.001
F001
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
1
F102
pu
0.01
F001
s
0.001
F001
pu
0.01
F001
s
0.001
F001
---
1
F300
---
1
F300
---
1
F102
---
1
F109
---
1
F102
pu
0.01
F001
pu
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
pu
0.01
F001
pu
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F102
DEFAULT
0 (Disabled)
10
600
50
B
200
0
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
10
600
50
200
0
0
0 (Disabled)
0 (Self-reset)
0 (Disabled)
10
50
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
50
75
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0
0
0
0
0
0
0
35
0
0
0 (Disabled)
B-31