B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 14 of 59)
ADDR
REGISTER NAME
40B6
DNP Voltage Default Deadband
40B8
DNP Power Default Deadband
40BA
DNP Energy Default Deadband
40BC
DNP Power Factor Default Deadband
40BE
DNP Other Default Deadband
B
40C0
DNP IIN Time Synchronization Bit Period
40C1
DNP Message Fragment Size
40C2
DNP Client Address 3
40C4
DNP Client Address 4
40C6
DNP Client Address 5
40C8
DNP Number of Paired Binary Output Control Points
40C9
DNP TCP Connection Timeout
40CA
DNP Communications Reserved (22 items)
40E0
TCP Port Number for the IEC 60870-5-104 Protocol
40E1
IEC 60870-5-104 Protocol Function
40E2
IEC 60870-5-104 Protocol Common Address of ASDU
40E3
IEC 60870-5-104 Protocol Cyclic Data Transmission Period
40E4
IEC 60870-5-104 Current Default Threshold
40E6
IEC 60870-5-104 Voltage Default Threshold
40E8
IEC 60870-5-104 Power Default Threshold
40EA
IEC 60870-5-104 Energy Default Threshold
40EC
IEC 60870-5-104 Power Factor Default Threshold
40EE
IEC 60870-5-104 Other Default Threshold
40F0
IEC 60870-5-104 Client Address (5 items)
4104
IEC 60870-5-104 Redundancy Port Enabled/Disabled
4105
Port 2 IP Address
4107
Port 2 IP Subnet Mask
4109
Port 2 Gateway IP Address
410B
PRT2 Ethernet Operation Mode
410C
PRT2 Redundancy Enabled
410D
Port 3 IP Address
410F
Port 3 IP Subnet Mask
4111
Port 3 Gateway IP Address
4113
Port 3 Ethernet Operation Mode
4114
PRT1 GOOSE Enabled
4115
PRT2 GOOSE Enabled
4116
PRT3 GOOSE Enabled
4117
IEC Communications Reserved (39 items)
413E
High Enet Traffic Function
413F
High Enet Traffic Events
4140
DNP Object 1 Default Variation
4141
DNP Object 2 Default Variation
4142
DNP Object 20 Default Variation
4143
DNP Object 21 Default Variation
4144
DNP Object 22 Default Variation
4145
DNP Object 23 Default Variation
4146
DNP Object 30 Default Variation
4147
DNP Object 32 Default Variation
Ethernet Switch (Read/Write Setting)
4148
Ethernet Switch IP Address
414A
Ethernet Switch Modbus IP Port Number
414B
Ethernet Switch Port 1 Events
414C
Ethernet Switch Port 2 Events
414D
Ethernet Switch Port 3 Events
B-22
RANGE
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
1 to 10080
30 to 2048
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 32
10 to 7200
0 to 1
0 to 65535
0 to 1
0 to 65535
1 to 65535
0 to 100000000
0 to 100000000
0 to 100000000
0 to 100000000
0 to1
0 to 100000000
0 to 4294967295
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
1 to 2
1 to 3
0 to 3
0 to 3
0 to 3
0 to 3
1 to 5
0 to 5
0 to 4294967295
1 to 65535
0 to 1
0 to 1
0 to 1
L60 Line Phase Comparison System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F003
---
1
F003
---
1
F003
--
1
F003
---
1
F003
min
1
F001
---
1
F001
---
1
F003
---
1
F003
---
1
F003
---
1
F001
s
1
F001
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
1
F001
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
0.01
F001
---
1
F003
---
1
F003
---
1
F126
---
1
F003
---
1
F003
---
1
F003
---
1
F192
1 (Full-Duplex)
---
1
F126
---
1
F003
---
1
F003
---
1
F003
---
1
F192
1 (Full-Duplex)
---
1
F102
---
1
F102
---
1
F102
---
1
F001
---
1
F102
---
1
F102
---
1
F001
---
1
F001
---
1
F523
---
1
F524
---
1
F523
---
1
F523
---
1
F001
---
1
F525
---
1
F003
---
1
F001
---
1
F102
---
1
F102
---
1
F102
DEFAULT
30000
30000
30000
30000
30000
1440
240
0
0
0
0
120
0
2404
0 (Disabled)
0
60
30000
30000
30000
30000
100
30000
0
0 (No)
56554706
4294966272
56554497
0 (No)
56554706
4294966272
56554497
1 (Enabled)
1 (Enabled)
1 (Enabled)
0
0 (Disabled)
0 (Disabled)
2
2
0 (1)
0 (1)
0 (1)
0 (1)
1
0 (1)
3232235778
502
0 (Disabled)
0 (Disabled)
0 (Disabled)