B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 24 of 59)
ADDR
REGISTER NAME
60E1
87PC Channel Loss
60E2
87PC Block
60E4
87PC Target
60E5
87PC Events
60E6
87PC Scheme Select
B
60E7
87PC Scheme Signal
60E8
87PC Signal Source
60E9
87PC FDL Pickup
60EB
87PC FDH Pickup
60EC
87PC Mixed Signal K
60F0
87PC Phase Delay Channel 1
60F2
87PC Phase Delay Channel 2
60F8
87PC Transient Pickup
60FD
87PC Asymmetry Channel 1
6104
87PC Asymmetry Channel 2
6106
87PC Stability Angle
6107
87PC Transient Reset
6108
87PC Received Volts Channel 1
6109
87PC Received Volts Channel 2
610A
87PC High-Speed Contact 1
610B
87PC High-Speed Contact 2
610C
87PC FDL AUX
610E
87PC FDH AUX
6110
87PC Reset Delay
6111
87PC Mixed Signal Reference Angle
6112
87PC Trip Security
6113
87PC Second Coincidence Timer
6114
87PC Enhanced Stability Angle
6115
87PC FDH Supervision
6117
87PC Pickup Delay
6118
87PC Stop Tx
611A
87PC Tx Reset Delay
Negative Sequence Time Overcurrent (Read/Write Grouped Setting) (2 modules)
6300
Negative Sequence Time Overcurrent 1 Function
6301
Negative Sequence Time Overcurrent 1 Signal Source
6302
Negative Sequence Time Overcurrent 1 Pickup
6303
Negative Sequence Time Overcurrent 1 Curve
6304
Negative Sequence Time Overcurrent 1 Multiplier
6305
Negative Sequence Time Overcurrent 1 Reset
6306
Negative Sequence Time Overcurrent 1 Block
6308
Negative Sequence Time Overcurrent 1 Target
6309
Negative Sequence Time Overcurrent 1 Events
630A
Reserved (7 items)
6311
...Repeated for Negative Sequence Time Overcurrent 2
Negative Sequence Instantaneous Overcurrent (Read/Write Grouped Setting) (2 modules)
63C0
Negative Sequence Instantaneous OC 1 Function
63C1
Negative Sequence Instantaneous OC 1 Signal Source
63C2
Negative Sequence Instantaneous Overcurrent 1 Pickup
63C3
Negative Sequence Instantaneous Overcurrent 1 Delay
63C4
Negative Sequence Instantaneous OC 1 Reset Delay
63C5
Negative Sequence Instantaneous Overcurrent 1 Block
B-32
RANGE
0 to 500
0 to 4294967295
0 to 2
0 to 1
0 to 8
0 to 2
0 to 1
0.02 to 15
0.05 to 15
0 to 0.25
0 to 30
0 to 30
0 to 65.535
-5 to 5
-5 to 5
40 to 140
0 to 65.535
0 to 125
0 to 125
0 to 64
0 to 64
0 to 4294967295
0 to 4294967295
0 to 200
0 to 359
0 to 1
10 to 200
40 to 180
0 to 4294967295
0 to 50
0 to 4294967295
0 to 1000
0 to 1
0 to 5
0 to 30
0 to 16
0 to 600
0 to 1
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 30
0 to 600
0 to 600
0 to 4294967295
L60 Line Phase Comparison System
APPENDIX B
UNITS
STEP
FORMAT
ms
1
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F088
0 (2TL-TR-SPC-
---
1
F150
---
1
F089
pu
0.01
F001
pu
0.01
F001
---
0.01
F001
ms
0.1
F001
ms
0.1
F001
s
0.001
F001
ms
0.1
F002
ms
0.1
F002
degrees
5
F001
s
0.001
F001
V
0.1
F001
V
0.1
F001
---
1
F490
---
1
F490
---
1
F300
---
1
F300
ms
1
F001
°
1
F001
---
1
F534
ms
1
F001
°
5
F001
---
1
F300
ms
1
F001
---
1
F300
ms
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F103
0 (IEEE Mod Inv)
---
0.01
F001
---
1
F104
0 (Instantaneous)
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
DEFAULT
0
0
0 (Self-reset)
0 (Disabled)
2FC)
0 (MIXED I_2 -
K*I_1)
0 (One Source
Current)
50
75
20
0
0
30
0
0
75
30
120
120
0
0
0
0
30
0
0 (First
Coincidence)
40
110
0
0
0
0
0 (Disabled)
0 (SRC 1)
1000
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
0
0
0
GE Multilin