Chapter 8 Measure Mode – Basic Tab
Full Scan
Understanding
Full Scan Results
(table)
164
When the marker is on a channel, the top of the marker is dark, and
overstrike portion of the channel is light gray.
1 To move the marker, use the left and right arrow keys.
With each non-continuous key press, the marker moves left or
right to the next channel.
You can also use the keypad to type the channel number.
2 Press ENTER.
3 To adjust the graph for best viewing of the signal level measure-
ments, use the up and down arrows.
Each arrow key press changes the reference setting by one (1)
dB. Reference level ranges are -40 to +60 dBmV.
NOTE
To perform a repetitive movement of the marker, press and hold the
left or right arrow key.
NOTE
An audio reading is not applicable to single type, DOCSIS or digital
channels.
The Full Scan measurement mode provides two views (Graph and
Table). Both views continuously update measurements for all the
channels. Both views also display all signal level measurements in the
current user-selected signal level units as specified in
erences" on page
43.
The Full Scan Table view displays each available channel number,
their video level readings, and available first and second video audio
deltas.
The highlighted channel in the Table view corresponds to the marked
channel from the Graph view and vice-versa.
When a channel reading is outside the limit boundaries, a Fail icon is
displayed and an up or down arrow is displayed to the right of the
Channel Status area below.
When you press the up or down arrows continuously, the highlight bar
moves faster.
"Regional Pref-
DSAM Help User Guide
Rev. 001