JDS Uniphase MP Series User Manual

JDS Uniphase MP Series User Manual

Usb optical power meter

Advertisement

Quick Links

MP-SerieS
USB OPtical POwer Meter
ZP-PKG-0529
REV 1
Miniature USB optical power meter with
FiberChekPRO™ integration
USer ManUal

Advertisement

Table of Contents
loading

Summary of Contents for JDS Uniphase MP Series

  • Page 1 MP-SerieS USB OPtical POwer Meter Miniature USB optical power meter with FiberChekPRO™ integration USer ManUal ZP-PKG-0529 REV 1...
  • Page 2 Notice Every effort was made to ensure that the information in this document was accurate at the time of printing. However, information is subject to change without notice, and JDSU reserves the right to provide an addendum to this document with information not available at the time that this document was created.
  • Page 3: Table Of Contents

    taBle Of cOntentS Overview ........................4 Hardware Features ...................4 Software Features .....................5 SOftware inStallatiOn .................6 System Requirements ..................6 OperatiOn prOcedureS ................7 Hardware Recognition ..................7 Software Controls for OPM ................8 Controls........................9 repOrtS ........................11 Default Path ....................... 11 SpecificatiOnS ....................12 MP-60 Specifications ................... 12 MP-80 Specifications ...................
  • Page 4: Overview

    Overview The Mp-series Optical power Meter (OpM) is a small form- factor device that measures optical power via a USB 2.0 connection to a PC/laptop. This unique device is used in conjunction with FiberChekPRO software, allowing the user to take stand alone Optical Power Measurements and also integrate the measurements with fiber inspection and certification.
  • Page 5: Software Features

    Software features FiberChekPRO integrates OPM functionality with fiber end face inspection, analysis and archiving. Using this program for inspection also requires a JDSU digital microscope. Further information on the fiber inspection and analysis capabilities can be found in the FiberChekPRO user manual. This manual primarily focuses on the functions associated with the MP-series hardware and the USB Power Meter.
  • Page 6: Software Installation

    SOftware inStallatiOn System requirements (Minimum) • 50 MB of hard drive space for software Insert the software installation disk into your CD drive. Follow the setup wizard for FiberChekPRO: a. At the Welcome screen, click Next > to continue b. At the Licence Agreement, select “I Accept the Agreement,”...
  • Page 7: Operation Procedures

    OperatiOn prOcedureS Hardware recognition Upon installing FiberChekPRO, the computer will automatically recognize any MP-series OPM devices that are connected to the USB input. If multiple devices are connected, simply open additional applications accordingly. JdSu uSB OpMs compatible with fiberchekprO Mp-series fi-series connects with Pc USB 2.0...
  • Page 8: Software Controls For Opm

    Software controls for OpM The Optical Power Meter menu allows you to configure options when using a USB- enabled JDSU OPM, such as the FI-series or MP-series. • Checking the box next to link OpM readings with fiber analysis allows you to associate power meter readings with a fiber analysis (see pg 10 for more details).
  • Page 9: Controls

    controls The power reading is displayed below the device drop- down menu. Users can select the measurement type (dBm, dB, mW) and wavelength (780, 820, 980, 1300, 1310, 1480, 1490, 1550, 1625 nm) from the blue drop-down menus. The ref button allows users to measure a relative power (attenuation) in a link loss test, which is measured in dB.
  • Page 10 The StOre button allows the user to capture the reading and comments in an .CSV log. The log location can be specified in the Setup/Optical Power Meter menu. The Notes field allows you to add comments about the stored reading. NOTE: You can also log by briefly pressing the button on the USB OPM device.
  • Page 11: Reports

    repOrtS Archived logs can be opened by either browsing to the defined path: default path for windows Xp: C:\Documents and Settings\pc username\My Documents\JDSU\FiberChekPRO\Archives\OPM Logs default path for windows 7: C:\Users\pc username\Documents\JDSU\FiberChekPRO\ Archives\OPM Logs each archived log includes the following data: •...
  • Page 12: Specifications

    Mp-60 Specifications 86 x 25 x 19 mm Dimensions (3.4 x 1.0 x 0.8 in) 14 g (0.5 oz) weight USB 2.0 USB type Universal 2.5 mm and connector input 1.25 mm connectors dB, milliwatt, dBm Measurement types USB port on PC or laptop Power source –65 to +10 dBm Display range...
  • Page 13: Specifications

    Mp-80 Specifications 86 x 25 x 19 mm (3.4 x 1.0 x Dimensions 0.8 in) 14 g (0.5 oz) weight USB 2.0 USB type Universal 2.5 and connector input 1.25 mm connectors dB, milliwatt, dBm Measurement types USB port on PC or laptop Power source –50 to +26 dBm Display range...
  • Page 14 This page left intentionally blank. MP-SERiES USB POwER MEtER...
  • Page 15 This page left intentionally blank. USer ManUal...
  • Page 16 TEL: +852 2892 0990 FAX: +852 2892 0770 eMea TEL: +49 7121 86 2222 FAX: +49 7181 86 1222 www.jdsu.com/inspect Product specifications and descriptions in this document subject to change without notice. © 2012 JDS Uniphase Corporation. ZP-PKG-0529 REV 1...

Table of Contents