Needle guard and needle guard plate

16.2 Setting the needle guard plate

The needle guard plate is supposed to prevent the needle from being de-
flected when the loop is taken up on machines without a thread cutter.
Proper setting
When the hook tip moves to the left and reaches the needle, it must not
be possible to press the needle against the direction of sewing.
Fig. 79: Setting the needle guard plate
(1) - Needle
(2) - Needle guard plate
To set the needle guard plate:
1. Open the hook covers ( p. 30).
2. Disassemble the throat plate ( p. 31).
3. Loosen the screw (3).
4. Set the needle guard plate (2) such that the needle (1) passes freely
5. Tighten the screw (3).
Service Instructions 195 - 00.0 - 12/2017
WARNING
Risk of injury!
Crushing, cutting and punctures are possible.
Only set the needle guard plate when the machine
is switched off.
between hook and needle guard plate (2).
(3) - Screw
79