Error code
6365
6366
6367
7202
7203
7212
7213
7222
7223
7801
7802
7803
8401
8402-8405
144
Type
Possible cause
Information
Internal EEprom
defective
Information
Internal EEprom defective
and external data not valid
(emergency operating
features only)
Information
Internal EEprom defective
and external EEprom not
connected
(emergency operating
features only)
Information
DACextension box boot
error
Information
Checksum error during
update
Information
DA stepper card 1 boot
error
Information
Checksum error
occurred while updating
DA stepper card 2
Information
DA stepper card 2 boot
error
Information
Checksum error
occurred while updating
DA stepper card 2
Information
Software version error
(DAC classic only; only
the functions of the
DAC basic will remain
available)
Information
Software update error
(DAC classic only; only
the functions of the
DAC basic will remain
available)
Information
Communication error
(DAC classic only; only
the functions of the
DAC basic will remain
available)
Error
Watchdog
Error
Internal error
Troubleshooting
Remedial action
• Replace control
• Replace control
• Replace control
Check connection cables
- Software update
• - Replace DACextension box
Check connection cables
- Software update
• - Replace DACextension box
Check connection cables
- Software update
• - Replace DACextension box
Check connection cables
- Software update
• - Replace DACextension box
Check connection cables
- Software update
• - Replace DACextension box
Check connection cables
- Software update
• - Replace DACextension box
Software update
• - Replace the control
Another software update
• - Replace the control
Restart of the control
- Software update
• - Replace the control
Software update
- Machine ID reset
• - Replace the control
Software update
- Machine ID reset
• - Replace the control
Service Instructions 195 - 00.0 - 12/2017

Advertisement

Table of Contents
loading