Dürkopp Adler 195 Service Instructions Manual page 142

Hide thumbs Also See for 195:
Table of Contents

Advertisement

Error code
1004
1005
1006
1007
1008
1010
1011
1012
1052
1053
1054
1055
1203
140
Type
Possible cause
Error
Sewing motor error:
Incorrect sewing motor
direction of rotation
Error
Motor blocked
Error
Maximum speed
exceeded
Error
Error in the reference run • Replace encoder
Error
Encoder error
Error
External synchronizer
plug (Sub-D, 9-pin) not
connected
Error
Encoder Z pulse missing • Switch off the control.
Error
Synchronizer fault
Error
Sewing motor
overcurrent, internal
current increase >25 A
Error
Sewing motor
overvoltage
Error
Internal short circuit
Error
Sewing motor overload
Information
Position not reached
(during thread cutting,
reversal, etc.)
Troubleshooting
Remedial action
• Replace encoder
• Check plug assignment and
change, if necessary
• Check wiring in machine
distributor and change it, if
necessary
• Test motor phases and check
for correct value
• Eliminate stiff movement in the
sewing machine
• Replace encoder
• Replace the motor
• Replace encoder
• Perform reset
• Check machine class (t 51 04)
• Eliminate stiff movement in the
sewing machine
• Replace encoder
• Connect cable of external
synchronizer to control, use
correct connection (Sync)
• Only required for machines with
transmission!
Turn handwheel and switch on
the control again
• If error is not corrected, check
encoder
• Replace the synchronizer
• Check selection of class
• Replace control
• Replace sewing motor
• Replace encoder
• Check selection of class
• Replace control
• Replace control
• Eliminate stiff movement in
the sewing machine
• Replace encoder
• Replace sewing motor
• Check and, if necessary,
change controller settings.
Mechanical changes to the
machine. (e. g. thread cutting
setting, belt tension, etc.)
• Check position (thread lever at
top dead center)
Service Instructions 195 - 00.0 - 12/2017