Troubleshooting

Problem
1. Shaft rotates slowly or not at all
2. Operation is erratic or not responsive
3. Shaft will not fully rotate
4. Selected position cannot be maintained
3121813
Table 4-1. Troubleshooting
Cause
a. Insufficient torque output
b. Low rate of fluid flow
c. Control or counterbalance valve has internal
leak
d. Piston and/or shaft seal leak
e. Corrosion build-up on the thrust surfaces
f. Swollen seals and composite bearings caused
by incompatible hydraulic fluid
a. Air in actuator
a. Twisted or chipped gear teeth
b. Port fittings are obstructing the piston
a. Control or counterbalance valve has internal
leak
b. Piston and/or shaft seal leak
c. Air in actuator
– JLG Lift –
SECTION 4 - BOOM & PLATFORM
Solution
a. Verify correct operating pressure. Do not
exceed OEM's pressure specifications. Load may
be above maximum capacity of the actuator.
b. Inspect ports for obstructions and hydraulic
lines for restrictions and leaks.
c. Disconnect hydraulic lines and bypass valve.
Leave valve ports open and operate the actuator
through housing ports (do not exceed OEM's
operating pressure). The valve must be replaced if
a steady flow of fluid is seen coming from the valve
ports.
d. Remove the plug and the housing's valve ports.
Operate the actuator through the housing ports.
Conduct the internal leakage test as described in
the Testing section on page 24 of this manual.
e. Re-build the actuator. Remove all rust then pol-
ish. Replacement parts may be needed.
f. Re-build the actuator. Use fluid that is compati-
ble with seals and bearings.
a. Purge air from actuator. See bleeding proce-
dures.
a. Check for gear binding. Actuator may not be
able to be re-built and may need to be replaced.
Damage could be a result of overload or shock.
b. Check thread length of port fittings. Fittings
should during stroke not reach inside the housing
bore.
a. Disconnect hydraulic lines and bypass valve.
Leave valve ports open and operate the actuator
through housing ports (do not exceed OEM's
operating pressure). The valve must be replaced if
a steady flow of fluid is seen coming from the valve
ports.
b. Remove the plug and the housing's valve ports.
Operate the actuator through the housing ports.
Conduct the internal leakage test as described in
the Testing section on page 24 of this manual.
c. Purge air from actuator. See bleeding proce-
dures
4-33