conductors of the harness.
5. Cut wire 106 going to the Engine/Generator Control-
ler after the existing connection point and install the
conductors that lead to the new inline fuse holder.
Use insulated butt splice connectors for these con-
ductors.
3121813
SECTION 3 - CHASSIS & TURNTABLE
6. Re-install the harness with the new fuse in place.
7. Reconnect the lift and APU start battery. The APU is
now ready for use.
– JLG Lift –
3-71