CALIBRATIONS
CONTROLLER CALS
TEMPERATURE ...
TRACTION I ...
PUMP I ...
TILTdelayIN ...
TILTdelayOUT ...
MACHINE CALS
BRAKE
PUMP@0%
PUMP@100%
Vflow@0%
Vflow@100%
Vlift@0%
Vlift@100%
Vswing@0%
Vswing@100%
SPEEDprop1 ...
SPEEDprop2 ...
SPEEDint ...
PLUGmax ...
3121813
Table 6-8. Calibration Descriptions
Not available at password level 2; can be viewed but not changed at level 1
Displays/adjusts heatsink temperature calibration
The setting should not be altered from that set during manufacture
Displays/adjusts traction motor current calibration
The setting should not be altered from that set during manufacture
Displays/adjusts pump motor current calibration
The setting should not be altered from that set during manufacture
Displays/adjusts how long the tilt sensor must indicate a tilted condition before it is registered
The setting should be adjusted to optimize controller response to a sudden tilt, while minimizing spurious tilt indica-
tions during acceleration & deceleration
Displays/adjusts how long the tilt sensor must indicate a not-tilted condition before it is registered
The setting should be adjusted to optimize controller response to a sudden tilt, while minimizing spurious tilt indica-
tions during acceleration & deceleration
Displays/adjusts brake release speed
The setting should be adjusted to release the brakes in the desired time, with minimal effect on other boom functions
Displays/adjusts minimum pump%on
The setting should be adjusted to minimize speed variations when functions are used individually and in combina-
tions
Displays/adjusts maximum pump%on
The setting should be adjusted to minimize speed variations when functions are used individually and in combina-
tions
Displays/adjusts minimum flow control proportional valve%on
Displays/adjusts maximum flow control proportional valve%on
Displays/adjusts minimum lift proportional valve%on
Displays/adjusts maximum lift proportional valve%on
Displays/adjusts minimum swing proportional valve%on
Displays/adjusts maximum swing proportional valve%on
Displays/adjusts speed control PID algorithm proportional term in traction mode
The setting should be adjusted to optimize speed control
Displays/adjusts speed control PID algorithm proportional term in plugging mode
The setting should be adjusted to optimize speed control
Displays/adjusts speed control PID algorithm integral term in traction & plugging mode
The setting should be adjusted to optimize speed control
Displays/adjusts maximum plugging current
The setting should be adjusted to ensure that the vehicle can be safely stopped when being driven down maximum