6.2

Confirming Error Messages

GP-GL Command Errors

Error No.
An order that cannot be recognized was forwarded.
Noise was input when the computer was turned ON.
E02001
The setting for the device the software will output to
has changed.
The settings on the plotter's interface have changed.
A numerical parameter of a command has exceeded
the acceptable range.
E02004
The setting for the device the software will output to
has changed.
The settings on the plotter's interface have changed.
An error related to receipt of data has occurred within
the interface.
E02005
The setting for the device the software will output to
has changed.
The settings on the plotter's interface have changed.
Data that exceeds the cutting area has been
E02006
received.

HP-GL Command Errors

When an HP-GL command error is displayed, the cause of such in most cases is one of the two reasons listed
below.
The setting for the model the application software will output to has changed.
The settings on the interface of the device have changed.
If one of these reasons has caused the error, take the measures listed below to resolve the problem.
Fix the setting for the model the application software will output to.
Fix the settings on the interface of the device.
Error No.
E03001
An order that cannot be recognized was executed.
Error 1
E03002
The value of a parameter was incorrectly specified.
Error 2
E03003
A parameter that cannot be used was executed.
Error 3
E03005
A character set that cannot be used was specified.
Error 5
E03006
The coordinates of a command have been specified
Error 6
outside of the cutting area.
E03007
An overflow of the buffer memory has occurred while
Error 7
processing the downloadable character buffer or
polygon buffer, etc.
E03010
While executing an output order, another output order
Error 10
was executed.
Displayed
Displayed
Chapter 6 Troubleshooting
Solution
Touch the
(Confirm).
In the menu of the software, perform settings for
operating the device.
Fix the setting of the software interface.
Fix the settings on the plotter's interface.
In the menu of the software, perform settings for
operating the device.
Fix the setting of the software interface.
Fix the settings on the plotter's interface.
In the menu of the software, perform settings for
operating the device.
Fix the setting of the software interface.
Fix the settings on the plotter's interface.
Confirm the data.
Confirm the size and cutting area of the media.
Confirm the settings for the scale.
Confirm the settings for the size of steps.
Solution
Execute a command that can be used.
Execute the command with a proper value for the
parameter.
Execute a parameter that can be used.
Specify a character set that can be used.
Execute the command with coordinates within the
cutting area.
Adjust the buffer size.
Check the program.
6-3