Boiler regulation

The ATTACK PELLET 30 AUTOMATIC Plus boiler for pellet combustion is regulated by control
panel placed on the upper covering.
1 – Main boiler switch – Plugs boiler into / off the power
2 – Burner mode switch – switches burner between stand-by and
operating mode
3 – Boiler thermostat – setting of boiler operating temperature
4 – Thermomanometer
5 – Reset button of the emergency thermostat – under cover
6 – Fuse 10 A / 250 V
Operation, parameters and settings of burner are described in the
appendix of this manual.
Technical parameters
Boiler type
Boiler output
Output range
Heat exchange area
Prescribed chimney draught
Max. operating water overpressure
Pressure loss of water
Boiler weight
Flue diameter
Boiler height
Boiler width
Boiler depth
Protection of el. parts
Max.el.input (by ignition)
Operating el. input
Boiler efficiency
Boiler class by CO emission (under EN 303-5)
Flue temperature by nominal output
Prescribed fuel
Average consumption
Volume of water in boiler
Range for setting of heat. water temperature
Connection voltage
Prescribed temperature of boiler return water within operation is 65°C.
Recommended operating temperature of water in boiler is 80–90°C.
The ATTACK, s.r.o. manufacturer reserves right for change of technical parameters and boiler dimensions without
previous announcement.
PELLET 30 AUTOMATIC Plus
kW
kW
2
m
Pa
kPa
Pa
152 ( T=10K); 38 ( T=20K)
kg
mm
mm
mm
mm
IP
W
W
%
°C
Wood pellets d=6–10 mm, l=35 mm max.
-1
kgh
l
°C
V/Hz
30
8–30
1,9
15–20
250
355
150
1220
575
1 250
IP 40
600
90
90,6
5
143
2,4–6,9
62
60–90
230/50
7