Usage of pellet burner

Pellet burner needs air for combustion. Thereby, boiler room must have opening for air inlet of at
2
least 200 cm
.
Pellet burner must not be started before it is verified, that smoke can freely flow through boiler and
chimney into atmosphere.
Pellet are supplied into burner from external feeder, connected to pellet container. Feeder has to be
installed under the 45°angle to ensure the best function and uniform fuel supply. Feeder should be
able to supply approximately 10 kg of pellets per hour of continual operation / requirement for
pellet supply.
Pellets must be stored in well ventilated room without moisture, or in specially designed container.
ATTENTION! Burner consists from components of high quality, that must not be replaced
with less quality spare parts. If components are replaced by other than original spare parts, warranty
expires.
Menu buttons nad their function
Burner functions are set by menu buttons under display. ( see also options of settings under the
Production settings – below).
How to change settings of pellet burner:
„S" – Menu / Enter: activation of
miscellanous records and access / save of
changes
„–" – Backspace from menu and
decreasement of adjustable values
„+" – Step forward in menu and
increasement of adjustable values
„ESC" – Exit/Escape: Exit from menu
without saving new values.
Values adjustable by user are given in the
following table:
MENU
OUTPUT SETTING
PELLETS DOSING
RECORD
BURN-DOWN
ADVANCED MENU Access into service menu through code
22
Explanation
Required output level (1, 2 or 3)
Setting of pellet supply
Error recording for control purposes
Instruction for burner burn-down