ATTACK PELLET 30 AUTOMATIC Plus Instructions For Use Manual page 30

Biomass boiler
Hide thumbs Also See for PELLET 30 AUTOMATIC Plus:
Table of Contents

Advertisement

14
Faulty sensor of thermostat
15
Faulty sensor of thermostat
16
Faulty circuit board
18
Fan works, while burner is under the
pause mode.
19
Fan does not work, when it should.
20
Fan runs too slowly.
21
First ignition trial failed
22
Pellet feeder is missing
23
Wrong pellet supply
24
Wrong amount of pellets supplied.
Faulty photocell
25
Cleaning does not work
26
Cleaning is slow
Error
Control
light
„network" does not
shine
Control light „burner
switch"
does
not
shine
Boiler
does
not
achieve
required
parameters
Door does not seal
30
Cause
No voltage in mains
Fork
of
plug
is
connected into el.socket
Wrong power switch
Damaged power plug
No requirement for heat supply
Disconnected
thermostat
Faulty switch
Water shortage in system
Too high output of pump
Boiler output is not sufficient for
the concrete system
Bad quality fuel
Low chimney draught
Strong chimney draught
Burner fault
Wrong glass cord
Exchange sensor.
Exchange sensor.
Exchange circuit board.
Exchange circuit board.
Exchange fuse of fan (800 mA); check
connection; exchange fan
Clean fan; Exchange fan
Set pellet dosis
Connect pellet feeder
Set pellet dosis
Set pellet dosis
Exchange photocell.
Check connection between circuit board
of scraper and main circuit board.
Clean the grate.
Solution
Check
incorrectly
Check
Exchange
Exchange
Find cause, solve and reset
emergency
Exchange
Refill
Correct overflow and switching
Matter of project
Combust prescribed fuel
New chimney, appropriate
connection
Place reducing flap into smoke
connection
See Appendix 1 or 2 – Error
detection
Exchange, tighten door hinges