6. REGULATION OF THE BOILER AND THE HEATING SYSTEM

6.1 IN GENERAL

DANGER
If you tun the main switch off during the boiler operation, it has no regulation. Then, any
dangerous states may cause the serious health or property damage. Always let the fuel
completely burn out and the boiler cool down before turning the main switch off!
WARNING
Opening the upper and middle door of the feeding chamber or the bottom door of the
combustion chamber during the operation may cause accumulation of the flammable gases and
their explosion, this may cause serious damage to health or property. It is forbidden to open
any door behind the main door during the operation!
CAUTION

6.2 EMERGENCY ACTIONS

Boiler overheating
If the boiler is in WOOD mode and it starts to overheat and the functionality of the aftercooling
loop fails from any reason, do the following:
 Do not open any door of the boiler!
 Turn the boiler off by the STOP button and confirm the red emergency message „I really
want to stop the boiler"
 Start all the pumps, heating circuits, open all the 3-way valves (attention, the max.
temperature by the floor heating is 40 °C), to ensure the max. heat energy outtake from the
boiler
 Leave the boiler room and close the door.
 Open the thermostatic heads on all radiators (the heating season does not make
a difference), eventually let the domestic hot water flow - run hot water tap, if the boiler is
connected for the D.H.W. preparation as well
 Contact your installer
DANGER
Never turn the main switch off, nor disconnect the boiler from the electricity mains, when
the boiler gets overheated!!