How to change production settings
To change settings, select the required menu /parameters. Change actual values by pressing „+" .
O:...indicates actual value, N:...can be adjusted to new value. Values can be increased by „+" button
and decreased by „–". Change is confirmed and saved by „S" button. Not to save changes, press
„ESC" (Exit/Escape).
Please, do not make any changes before reading this manual!
Example:
EFFECT ADJ.
O: 1
N: 2
Reset of production settings
To reset production settings, select advanced menu and enter password (code = figure by „O" + 5).
Then, select Menu / setting and press „S". Go to „return to production" and press „S" again.
Thereby, the production settings are reset.
In the following way you can also save your own settings: by pressing „+" you get to „Save
settings?". Save your settings by pressing „S". Exit from menu by the „ESC".
Regulation of pellet dosing
Before starting the burner, it is necessary to adjust pellet feeding through parameter „Pellet trim" in
Advanced menu. Thermostat must not turn the heating on, while setting.
Firstly, set the „Heat value" parameter to value given by your pellet producer (e.g. by 4,8 kWh/kg –
set parameter to 48, etc.).
Now, fasten plastic bag around opening of pellet feeder. Confirm by „S" and keep the instructions.
Weigh pellets fallen into the plastic bag, enter weight in gramms by „+/–" buttons and press „S" to
save value. This setting has to be done within 15 minutes. Otherwise, burner switches to standby
mode. Weigh the pellets very precisely!
After setting of the above mentioned parameters, all other parameters related with pellet supply are
automatically adjusted by control system.