Boiler regulation with room thermostat
Boiler is controlled by the room thermostat, connected to the terminal contacts (TP -L1/L2) instead
of interconnection, that has to be removed. The required boiler temperature will be considered as
well. Also other type of requirement can be installed instead of the room thermostat – e.g.
programmable regulator of heating.
ATTENTION!
There is dangerous contact voltage of 230 V on the connection contacts of the room
thermostat! Boiler must be disconnected from electricity by any action into the electrical
terminal or boiler electrical installation!
Boiler protection
Boiler is equipped with emergency thermostat. If the boiler temperature exceeds 110°C, boiler
safely gets out of order. When the boiler temperature decreases, it is possible to start the boiler
again by using the reset button placed on the front control panel.
Fuel refill
Fuel is refilled in the container that belongs to the optional boiler accessories. Fuel should be
refilled before the pellets in the container are totally consumed.
ATTENTION! Fuel container can be open only when fuel is being refilled, eventually by
cleaning. Container has to be closed during the boiler operation.
Ash removing
The ATTACK PELLET 30 AUTOMATIC Plus boiler is equipped with device for automatic ash
removing into the detachable box. It is necessary to check the box 2x per season and to empty it, if
necessary. Stop the boiler for a short time, when removing the ash container.
When emptying the box (see the picture):
1. Close inlet opening into the container by pulling the lever on the container rear side fully to
the left
2. Release lever catches on container sides
3. Detach container from inlet tube of door cover by pulling it to yourself
4. Remove the ash
Do the reverse procedure to fit the container back.
When cleaning bottom of the combustion chamber, stop the boiler for a short time. Empty the iron
ashtray, eventually – sweep the boiler bottom. Ash tray is placed in the bottom part of boiler, behind
the ash tray door. Use gloves by manipulation with ash tray to prevent burning your hands. When
the ash is removed, it is necessary to put the ash tray back and to close the ash tray door tightly.
WARNING – Do not operate the boiler without the ash container fixed with the closed upper
cover (possible flue leakage) – life safety hazard!