Time of feeder operation:
STOKERTIME
ENTER
<
>
Test:
MENU/TEST
ENTER
<
> EXIT
components. In manual mode you can test each component individually, by pressing „S" for start
and „ESC" for stop. To move forward / backwards, press „+/–".
Components are displayed in the following order:
Ventilator (rotations should be stable at 2.000 during the ventilator testing);
Pellet feeder (start / stop by using „S" / „ESC" buttons)
Grate (moves out by pressing „S" and moves back by pressing „ESC". Here you can see, how many
mA are consumed by unit for shifting. It should not exceed 1 800 mA – this is limit for the „Grate
blockage" message).
Other displayed options: Actual value, if thermal probe is connected; actual photocell value;
indicates light (On / Off); application close.
Settings:
MENU/SETTINGS
ENTER
<
> EXIT
Production settings.
-
"Boot settings" – here you can set original settings.
-
"Save settings" – definitive adjustment of burner settings, made by installer. This enables easier
browsing of settings for the case of too many parameter changes.
-
"Production settings" – original settings are saved here to be rebooted, when necessary .
Record:
MENU/ERRORS
ENTER
> EXIT
ignitions, number of second ignitions, the newest errors.
-
"Number of errrors" – indicates every error code separately, e.g. E-CODE 10 (X). See page
30 to see the codes and explanation.
-
"Number of first ignitions"– indicates, how many times there was an ignition.
-
"Number of second ignitions" – indicates, how many second ignition trials were made by
burner (i.e. how many times did the first trial fail).
-
"Last errors" – indicates error codes ordered by their frequency. It enables easier
troubleshooting.
Here you can see, how long did the pellet feeder work. You can use
it to calculate energy consumtpion, etc.
EXIT
Serves by troubleshooting. Here you can control components –
manually or automatically.
This function is very useful by solving problems with particular
Here you can set settings saved by installation. Production and
installation settings can be reset here as well.
Three main options are available: Boot settings, Save settings and
All errors are saved and displayed here together with their
frequency. Total number of ignition trials is saved here as well.
Four options are accessible: number of errors, number of first