3.13.4 Exit unit
CAUTION
The temperature gets high in the vicinity of the fuser
replacing it, make sure that fuser unit has cooled.
[B]
Service Manual
CLX-9250/9350 series
3. Replacemen
[A]
nt Procedures
unit. When replacing it, you may get burned. Before
1. Open the Cover-Side.
2. Remove 2 fuser locking screws.
3. Remove the Fuser unit by holding the
handles [A].
4. Remove 1 screw and harness cover [B].
3-1
11
SAMSUNG ELECTRONICS