Samsung CLX-9350ND Service Manual page 364

Digital color laser mfp
Hide thumbs Also See for CLX-9350ND:
Table of Contents

Advertisement

● Code :
A2-1310
A2-1311
A2-1410
A2-1411
A2-1510
A2-1511
A2-1810
A2-1811
A2-2310
A2-2311
A2 2410
A2-2410
A2-2411
A2-2510
A2-2511
A2-2810
A2-2811
A2-2910
A2-2911
U3-1310
U3-1311
● Symptom / Cause :
Fan does not operate.
- Fan overheats. / There is any foreign matter around
A2-1310 / A2-1311 : SMPS In Fan
A2-1410 / A2-1411: SMPS Out Fan
A2-1510 / A2-1511 : Duplex Fan
A2-1810 / A2-1811 : HDD Fan
A2-2310 / A2-2311 : FUSER FAN
A2-2410 / A2-2411 : LSU FAN 1
A2-2510 / A2-2511 : LSU FAN 2
A2-2810 / A2-2811: OZONE FAN
U3-1310 / U3-1311 : Scan Fan
● Troubleshooting method :
1. Remove the foreign matter around the fan.
2. Turn the machine off and on.
3. Check the circuit related the fan.
●Replacement part
A2-1310 / A2-1311 /A2-1410 / A2-1411 /A2-1810 / A2-
A2-1510 / A2-1511 / A2-2310 / A2-2311 /A2-2410 / A2
U3-1310 / U3-1311 : JC31-00127A
Service Manual
CLX-9250/9350 series
7. Troubles
shooting
● Error message :
Actuator Fan Failure
e #A2-1310: Please open/close door.
Actuator Fan Signal
Failure : #A2-1311. Please open/close door.
Actuator Fan Failure
e #A2-1410: Please open/close door.
Actuator Fan Signal
Failure : #A2-1411. Please open/close door.
Actuator Fan Failure
Actuator Fan Failure
e #A2 1510: Please open/close door
e #A2-1510: Please open/close door.
Actuator Fan Signal
Failure : #A2-1511. Please open/close door.
Actuator Fan Failure
e #A2-1810: Please open/close door.
Actuator Fan Signal
Failure : #A2-1811. Please open/close door.
Actuator Fan Failure
e #A2-2310: Please open/close door.
Actuator Fan Signal
Failure.#A2-2311:Please open/close door.
Actuator Fan Failure
e #A2-2410: Please open/close door.
Actuator Fan Signal
Failure.#A2-2411:Please open/close door.
Actuator Fan Failure
e #A2-2510: Please open/close door.
Actuator Fan Signal
Failure : #A2-2511. Please open/close door.
Actuator Fan Failure
e #A2-2810: Please open/close door.
Actuator Fan Signal
Failure : #A2-2811. Please open/close door.
Actuator Fan Failure
e : #A2-2910. Please open/close door.
Actuator Fan Signal
Actuator Fan Signal
Failure : #A2 2911 Please open/close door
Failure : #A2-2911. Please open/close door.
Actuator Fan Failure
e #U3-1310: Turn off then on.
Actuator Fan Failure
e #U3-1311: Turn off then on.
d the fan.
-1811 /A2-2510 / A2-2511 : JC31-00129A
2-2411/A2-2810 / A2-2811 : JC31-00130A
7-2
24
SAMSUNG ELECTRONICS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clx-9250nd

Table of Contents