4.5.6.3. Auto Color Tone Adjustment
• Diagnostics > Color Management > Auto Col
Purpose
Operation
Procedure
Verification
Specification
Reference
Service Manual
CLX-9250/9350 series
To correct image quality when
is recommended to be perform
imaging unit, and ITB, and rebo
Low Image Density
g
Change execution condition(s)
•
Page Count: The system e
printed pages since the las
•
Time Left Alone: The syste
returns from a power save
value.
Users can also execute the fun
Print out a test job and make su
Page Count
Time Left Alone
CLX-9250/9350 Series Service
CLX-9250/9350 Series Service
Failure
4.Servic
ce Mode
lor Tone Adjustment > Normal TRC Control
density of the image is poor. Normal TRC Control
p
ed after changing a unit, such as toner cartridge,
g g
oot.
y
y
y
Gradation Reproduction Failure
of Normal TRC Control.
xecutes Normal TRC Control based on the count of
st execution.
em executes Normal TRC Control when the system
mode and the rest time exceeds the configured
nction by pressing "Execute Now" button.
ure the image quality has recovered.
Def
fault
Min. Value
10
000
1
80
e Manual, Chapter 7.3.9 Low Image Density
e Manual, Chapter 7.3.13 Gradation Reproduction
4-4
43
,
p
Max. Value
500
1500
0
360
SAMSUNG ELECTRONICS
g ,