Ipv6 Pim-Sm Non-Scoped Zone Configuration Example - HP FlexNetwork 7500 Series Configuration Manual

Ip multicast
Hide thumbs Also See for FlexNetwork 7500 Series:
Table of Contents

Advertisement

(*, FF0E::101)
Protocol: pim-dm, Flag: WC
UpTime: 00:01:24
Upstream interface: NULL
Upstream neighbor: NULL
RPF prime neighbor: NULL
Downstream interface(s) information:
Total number of downstreams: 1
1: Vlan-interface100
(4001::100, FF0E::101)
Protocol: pim-dm, Flag: ACT
UpTime: 00:01:20
Upstream interface: Vlan-interface103
Upstream neighbor: 1002::2
RPF prime neighbor: 1002::2
Downstream interface(s) information:
Total number of downstreams: 1
1: Vlan-interface100
# Display IPv6 PIM multicast routing table information on Switch D.
[SwitchD] display ipv6 pim routing-table
Total 0 (*, G) entry; 1 (S, G) entry
(4001::100, FF0E::101)
Protocol: pim-dm, Flag: LOC ACT
UpTime: 00:02:19
Upstream interface: Vlan-interface300
Upstream neighbor: NULL
RPF prime neighbor: NULL
Downstream interface(s) information:
Total number of downstreams: 2
1: Vlan-interface103
2: Vlan-interface102
The output shows the following information:
Switches on the SPT path (Switch A and Switch D) have the correct (S, G) entries.
Switch A has a correct (*, G) entry.

IPv6 PIM-SM non-scoped zone configuration example

Network requirements
As shown in
OSPFv3 runs on the network.
Protocol: mld, UpTime: 00:01:20, Expires: -
Protocol: pim-dm, UpTime: 00:01:20, Expires: -
Protocol: pim-dm, UpTime: 00:02:19, Expires: -
Protocol: pim-dm, UpTime: 00:02:19, Expires: -
Figure
107: