Press menu key »
« in the Monitoring menu.
Display (example):
Select alarm parameter with »
Adjust alarm threshold with menu keys »
Repeatedly pressing key briefly: adjustments in
Keeping key pressed down:
Recommendation for setting MV alarm limits.
When the measured value for minute ventilation MV
has reached steady state:
Press »±30%« menu key.
The lower alarm limit is set to 30% below actual
minute volume, the upper alarm limit to 30% above
actual minute volume, but it will not exceed 15 L/min.
To leave menu:
Press »
« menu key.