APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 59 of 62)
ADDR
REGISTER NAME
D32D
IEC 61850 GGIO2.CF.SPCSO14.ctlModel Value
D32E
IEC 61850 GGIO2.CF.SPCSO15.ctlModel Value
D32F
IEC 61850 GGIO2.CF.SPCSO16.ctlModel Value
D330
IEC 61850 GGIO2.CF.SPCSO17.ctlModel Value
D331
IEC 61850 GGIO2.CF.SPCSO18.ctlModel Value
D332
IEC 61850 GGIO2.CF.SPCSO19.ctlModel Value
D333
IEC 61850 GGIO2.CF.SPCSO20.ctlModel Value
D334
IEC 61850 GGIO2.CF.SPCSO21.ctlModel Value
D335
IEC 61850 GGIO2.CF.SPCSO22.ctlModel Value
D336
IEC 61850 GGIO2.CF.SPCSO23.ctlModel Value
D337
IEC 61850 GGIO2.CF.SPCSO24.ctlModel Value
D338
IEC 61850 GGIO2.CF.SPCSO25.ctlModel Value
D339
IEC 61850 GGIO2.CF.SPCSO26.ctlModel Value
D33A
IEC 61850 GGIO2.CF.SPCSO27.ctlModel Value
D33B
IEC 61850 GGIO2.CF.SPCSO28.ctlModel Value
D33C
IEC 61850 GGIO2.CF.SPCSO29.ctlModel Value
D33D
IEC 61850 GGIO2.CF.SPCSO30.ctlModel Value
D33E
IEC 61850 GGIO2.CF.SPCSO31.ctlModel Value
D33F
IEC 61850 GGIO2.CF.SPCSO32.ctlModel Value
D340
IEC 61850 GGIO2.CF.SPCSO33.ctlModel Value
D341
IEC 61850 GGIO2.CF.SPCSO34.ctlModel Value
D342
IEC 61850 GGIO2.CF.SPCSO35.ctlModel Value
D343
IEC 61850 GGIO2.CF.SPCSO36.ctlModel Value
D344
IEC 61850 GGIO2.CF.SPCSO37.ctlModel Value
D345
IEC 61850 GGIO2.CF.SPCSO38.ctlModel Value
D346
IEC 61850 GGIO2.CF.SPCSO39.ctlModel Value
D347
IEC 61850 GGIO2.CF.SPCSO40.ctlModel Value
D348
IEC 61850 GGIO2.CF.SPCSO41.ctlModel Value
D349
IEC 61850 GGIO2.CF.SPCSO42.ctlModel Value
D34A
IEC 61850 GGIO2.CF.SPCSO43.ctlModel Value
D34B
IEC 61850 GGIO2.CF.SPCSO44.ctlModel Value
D34C
IEC 61850 GGIO2.CF.SPCSO45.ctlModel Value
D34D
IEC 61850 GGIO2.CF.SPCSO46.ctlModel Value
D34E
IEC 61850 GGIO2.CF.SPCSO47.ctlModel Value
D34F
IEC 61850 GGIO2.CF.SPCSO48.ctlModel Value
D350
IEC 61850 GGIO2.CF.SPCSO49.ctlModel Value
D351
IEC 61850 GGIO2.CF.SPCSO50.ctlModel Value
D352
IEC 61850 GGIO2.CF.SPCSO51.ctlModel Value
D353
IEC 61850 GGIO2.CF.SPCSO52.ctlModel Value
D354
IEC 61850 GGIO2.CF.SPCSO53.ctlModel Value
D355
IEC 61850 GGIO2.CF.SPCSO54.ctlModel Value
D356
IEC 61850 GGIO2.CF.SPCSO55.ctlModel Value
D357
IEC 61850 GGIO2.CF.SPCSO56.ctlModel Value
D358
IEC 61850 GGIO2.CF.SPCSO57.ctlModel Value
D359
IEC 61850 GGIO2.CF.SPCSO58.ctlModel Value
D35A
IEC 61850 GGIO2.CF.SPCSO59.ctlModel Value
D35B
IEC 61850 GGIO2.CF.SPCSO60.ctlModel Value
D35C
IEC 61850 GGIO2.CF.SPCSO61.ctlModel Value
D35D
IEC 61850 GGIO2.CF.SPCSO62.ctlModel Value
D35E
IEC 61850 GGIO2.CF.SPCSO63.ctlModel Value
D35F
IEC 61850 GGIO2.CF.SPCSO64.ctlModel Value
Remote Device Status (Read Only) (16 modules)
D360
Remote Device 1 StNum
D362
Remote Device 1 SqNum
GE Multilin
RANGE
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 4294967295
0 to 4294967295
D30 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F003
---
1
F003
DEFAULT
1
1
1
1
1
B
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
B-67