Table B–10: MODBUS MEMORY MAP (Sheet 29 of 62)
ADDR
REGISTER NAME
5D09
Ground Time Overcurrent 1 Target
5D0A
Ground Time Overcurrent 1 Events
5D0B
Reserved (6 items)
5D11
...Repeated for Ground Time Overcurrent 2
Ground Instantaneous Overcurrent (Read/Write Grouped Setting) (2 modules)
5DA0
Ground Instantaneous Overcurrent 1 Function
5DA1
Ground Instantaneous Overcurrent 1 Signal Source
5DA2
Ground Instantaneous Overcurrent 1 Pickup
5DA3
Ground Instantaneous Overcurrent 1 Delay
5DA4
Ground Instantaneous Overcurrent 1 Reset Delay
5DA5
Ground Instantaneous Overcurrent 1 Block
5DA7
Ground Instantaneous Overcurrent 1 Target
5DA8
Ground Instantaneous Overcurrent 1 Events
5DA9
Reserved (8 items)
5DB1
...Repeated for Ground Instantaneous Overcurrent 2
Setting Groups (Read/Write Setting)
5F70
Setting Group for Modbus Comms (0 means group 1)
5F71
Setting Groups Block
5F73
FlexLogic Operands to Activate Groups 2 through 6 (5
items)
5F7D
Setting Group Function
5F7E
Setting Group Events
Setting Groups (Read Only)
5F7F
Current Setting Group
Setting Group Names (Read/Write Setting)
5F8C
Setting Group 1 Name
5F94
Setting Group 2 Name
5F9C
Setting Group 3 Name
5FA4
Setting Group 4 Name
5FAC
Setting Group 5 Name
5FB4
Setting Group 6 Name
Autoreclose (Read/Write Setting) (1 module)
6200
Autoreclose 1 Function
6201
Autoreclose 1 Initiate
6203
Autoreclose 1 Block
6205
Autoreclose 1 Max Number of Shots
6206
Autoreclose 1 Manual Close
6208
Autoreclose 1 Manual Reset from LO
620A
Autoreclose 1 Reset Lockout if Breaker Closed
620B
Autoreclose 1 Reset Lockout On Manual Close
620C
Autoreclose 1 Breaker Closed
620E
Autoreclose 1 Breaker Open
6210
Autoreclose 1 Block Time Upon Manual Close
6211
Autoreclose 1 Dead Time Shot 1
6212
Autoreclose 1 Dead Time Shot 2
6213
Autoreclose 1 Dead Time Shot 3
6214
Autoreclose 1 Dead Time Shot 4
6215
Autoreclose 1 Reset Lockout Delay
6216
Autoreclose 1 Reset Time
6217
Autoreclose 1 Incomplete Sequence Time
6218
Autoreclose 1 Events
6219
Autoreclose 1 Reduce Max 1
621B
Autoreclose 1 Reduce Max 2
621D
Autoreclose 1 Reduce Max 3
GE Multilin
RANGE
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 30
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 5
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 5
---
---
---
---
---
---
0 to 1
0 to 4294967295
0 to 4294967295
1 to 4
0 to 4294967295
0 to 4294967295
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 655.35
0 to 655.35
0 to 655.35
0 to 655.35
0 to 655.35
0 to 655.35
0 to 655.35
0 to 655.35
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
D30 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F001
---
1
F300
---
1
F300
---
1
F102
---
1
F102
---
1
F001
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
---
F203
---
1
F102
---
1
F300
---
1
F300
---
1
F001
---
1
F300
---
1
F300
---
1
F108
---
1
F108
---
1
F300
---
1
F300
s
0.01
F001
s
0.01
F001
s
0.01
F001
s
0.01
F001
s
0.01
F001
s
0.01
F001
s
0.01
F001
s
0.01
F001
---
1
F102
---
1
F300
---
1
F300
---
1
F300
DEFAULT
0 (Self-reset)
0 (Disabled)
0
B
0 (Disabled)
0 (SRC 1)
1000
0
0
0
0 (Self-reset)
0 (Disabled)
0
0
0
0
0 (Disabled)
0 (Disabled)
0
(none)
(none)
(none)
(none)
(none)
(none)
0 (Disabled)
0
0
1
0
0
0 (Off)
0 (Off)
0
0
1000
100
200
300
400
6000
6000
500
0 (Disabled)
0
0
0
B-37