APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 7 of 62)
ADDR
REGISTER NAME
15C8
Direct Outputs Average Message Return Time 1
15C9
Direct Outputs Average Message Return Time 2
15CA
Direct Inputs/Outputs Unreturned Message Count - Ch. 1
15CB
Direct Inputs/Outputs Unreturned Message Count - Ch. 2
15D0
Direct Device States
15D1
Reserved
15D2
Direct Inputs/Outputs CRC Fail Count 1
15D3
Direct Inputs/Outputs CRC Fail Count 2
Field Unit Input/Output States (Read Only)
15E0
Field Unit Contact Input States (3 items)
15E3
Field Unit Contact Input Output Operand States (8 items)
15EB
Field Contact Output Physical States (8 items)
15F3
Field Contact Output Current States (8 items)
15FB
Field Contact Output Physical States (8 items)
1603
Field Shared Input States
1604
Field Shared Input Channel States
1605
Field Shared Input Test States
1606
Field Shared Output Operand States
1607
Field Latching Output Open Operand States
1608
Field Latching Output Close Operand States
1609
Field Latching Output Open Driver States
160A
Field Latching Output Close Driver States
160B
Field Latching Output Physical States
160C
Field Unit Online/Offline States
160D
Field RTD Input Trouble States
160E
Field Transducer Input Trouble States
Ethernet Fibre Channel Status (Read Only)
1610
Ethernet Primary Fibre Channel Status
1611
Ethernet Secondary Fibre Channel Status
1612
Ethernet Tertiary Fibre Channel Status
Field Unit RTD Actuals (Read Only) (8 modules)
16C0
Field RTD 1 Value
16C1
...Repeated for Field RTD 2
16C2
...Repeated for Field RTD 3
16C3
...Repeated for Field RTD 4
16C4
...Repeated for Field RTD 5
16C5
...Repeated for Field RTD 6
16C6
...Repeated for Field RTD 7
16C7
...Repeated for Field RTD 8
Field Unit Transducer Actuals (Read Only) (8 modules)
16C8
Field Transducer 1 Value
16CA
...Repeated for Field Transducer 2
16CC
...Repeated for Field Transducer 3
16CE
...Repeated for Field Transducer 4
16D0
...Repeated for Field Transducer 5
16D2
...Repeated for Field Transducer 6
16D4
...Repeated for Field Transducer 7
16D6
...Repeated for Field Transducer 8
Source Current (Read Only) (2 modules)
1800
Source 1 Phase A Current RMS
1802
Source 1 Phase B Current RMS
1804
Source 1 Phase C Current RMS
1806
Source 1 Neutral Current RMS
1808
Source 1 Phase A Current Magnitude
GE Multilin
RANGE
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 2
0 to 2
-32768 to 32767
-32.768 to 32.767
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
0 to 999999.999
D30 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
ms
1
F001
ms
1
F001
---
1
F001
---
1
F001
---
1
F500
---
1
F001
---
1
F001
---
1
F001
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F500
---
1
F134
---
1
F134
---
1
F134
°C
1
F002
---
0.001
F004
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
A
0.001
F060
DEFAULT
0
0
0
0
0
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Fail)
0 (Fail)
0 (Fail)
0
0
0
0
0
0
0
B-15