B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 34 of 62)
ADDR
REGISTER NAME
723E
Neutral Directional Overcurrent 1 Offset
723F
Neutral Directional Overcurrent 1 Pos Seq Restraint
7240
Reserved
7241
...Repeated for Neutral Directional Overcurrent 2
Negative-Sequence Directional Overcurrent (Read/Write Grouped Settings) (2 modules)
B
7260
Negative Sequence Directional Overcurrent 1 Function
7261
Negative Sequence Directional Overcurrent 1 Source
7262
Negative Sequence Directional Overcurrent 1 Type
7263
Neg Sequence Directional Overcurrent 1 Forward ECA
7264
Neg Seq Directional Overcurrent 1 Forward Limit Angle
7265
Neg Sequence Directional Overcurrent 1 Forward Pickup
7266
Neg Seq Directional Overcurrent 1 Reverse Limit Angle
7267
Neg Sequence Directional Overcurrent 1 Reverse Pickup
7268
Negative Sequence Directional Overcurrent 1 Target
7269
Negative Sequence Directional Overcurrent 1 Block
726B
Negative Sequence Directional Overcurrent 1 Events
726C
Negative Sequence Directional Overcurrent 1 Offset
726D
Negative Sequence Directional Overcurrent 1 Pos Seq
Restraint
726E
Reserved (3 items)
7271
...Repeated for Neg Seq Directional Overcurrent 2
Breaker Arcing Current Settings (Read/Write Setting) (2 modules)
7290
Breaker 1 Arcing Amp Function
7291
Breaker 1 Arcing Amp Source
7292
Breaker 1 Arcing Amp Init
7294
Breaker 1 Arcing Amp Init B
7296
Breaker 1 Arcing Amp Init C
7298
Breaker 1 Arcing Amp Delay
7299
Breaker 1 Arcing Amp Limit
729A
Breaker 1 Arcing Amp Block
729C
Breaker 1 Arcing Amp Target
729D
Breaker 1 Arcing Amp Events
729E
...Repeated for Breaker 2 Arcing Amp
Disconnect (Breaker) Switch (Read/Write Setting) (8 modules)
74A0
Disconnect Switch 1 Function
74A1
Disconnect Switch 1 Name
74A4
Disconnect Switch 1 Mode
74A5
Disconnect Switch 1 Open
74A7
Disconnect Switch 1 Block Open
74A9
Disconnect Switch 1 Close
74AB
Disconnect Switch 1 Block Close
74AD
Disconnect Switch 1 Phase A / Three-pole Closed
74AF
Disconnect Switch 1 Phase A / Three-pole Opened
74B1
Disconnect Switch 1 Phase B Closed
74B3
Disconnect Switch 1 Phase B Opened
74B5
Disconnect Switch 1 Phase C Closed
74B7
Disconnect Switch 1 Phase C Opened
74B9
Disconnect Switch 1 Operate Time
74BA
Disconnect Switch 1 Alarm Delay
74BC
Disconnect Switch 1 Events
74BD
Reserved (2 items)
74BF
...Repeated for Disconnect Switch 2
74DE
...Repeated for Disconnect Switch 3
74FD
...Repeated for Disconnect Switch 4
B-42
RANGE
0 to 250
0 to 0.5
0 to 1
0 to 1
0 to 5
0 to 1
0 to 90
40 to 90
0.015 to 30
40 to 90
0.015 to 30
0 to 2
0 to 4294967295
0 to 1
0 to 250
0 to 0.5
0 to 1
0 to 1
0 to 5
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 50000
0 to 4294967295
0 to 2
0 to 1
0 to 1
---
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 65.535
0 to 1
---
D30 Line Distance Protection System
APPENDIX B
UNITS
STEP
FORMAT
ohms
0.01
F001
---
0.001
F001
---
1
F001
---
1
F102
---
1
F167
---
1
F179
0 (Neg Sequence)
° Lag
1
F002
degrees
1
F001
pu
0.005
F001
degrees
1
F001
pu
0.005
F001
---
1
F109
---
1
F300
---
1
F102
ohms
0.01
F001
---
0.001
F001
---
1
F001
---
1
F102
---
1
F167
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
kA2-cyc
1
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
s
0.001
F003
---
1
F102
---
---
F001
DEFAULT
0
63
0
0 (Disabled)
0 (SRC 1)
75
90
50
90
50
0 (Self-reset)
0
0 (Disabled)
0
63
0
0 (Disabled)
0 (SRC 1)
0
0
0
0
1000
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
"SW 1"
0 (3-Pole)
0
0
0
0
0
0
0
0
0
0
70
0
0 (Disabled)
0