GE D30 Instruction Manual page 543

Line distance protection system, ur series
Hide thumbs Also See for D30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 37 of 62)
ADDR
REGISTER NAME
Distance Loop Impedance (Read Only)
7EC0
Dist Zab Mag
7EC1
Dist Zab Ang
7EC2
Dist Zbc Mag
7EC3
Dist Zbc Ang
7EC4
Dist Zca Mag
7EC5
Dist Zca Ang
7EC6
Dist Zag Mag
7EC7
Dist Zag Ang
7EC8
Dist Zbg Mag
7EC9
Dist Zbg Ang
7ECA
Dist Zcg Mag
7ECB
Dist Zcg Ang
Neutral Overvoltage (Read/Write Grouped Setting) (3 modules)
7F00
Neutral Overvoltage 1 Function
7F01
Neutral Overvoltage 1 Signal Source
7F02
Neutral Overvoltage 1 Pickup
7F03
Neutral Overvoltage 1 Pickup Delay
7F04
Neutral Overvoltage 1 Reset Delay
7F05
Neutral Overvoltage 1 Block
7F07
Neutral Overvoltage 1 Target
7F08
Neutral Overvoltage 1 Events
7F09
Neutral Overvoltage 1 Curves
7F0A
Reserved (7 items)
7F11
...Repeated for Neutral Overvoltage 2
7F22
...Repeated for Neutral Overvoltage 3
Auxiliary Undervoltage (Read/Write Grouped Setting
7F60
Auxiliary Undervoltage 1 Function
7F61
Auxiliary Undervoltage 1 Signal Source
7F62
Auxiliary Undervoltage 1 Pickup
7F63
Auxiliary Undervoltage 1 Delay
7F64
Auxiliary Undervoltage 1 Curve
7F65
Auxiliary Undervoltage 1 Minimum Voltage
7F66
Auxiliary Undervoltage 1 Block
7F68
Auxiliary Undervoltage 1 Target
7F69
Auxiliary Undervoltage 1 Events
7F6A
Reserved (7 items)
Auxiliary Overvoltage (Read/Write Grouped Setting)
7FA0
Auxiliary Overvoltage 1 Function
7FA1
Auxiliary Overvoltage 1 Signal Source
7FA2
Auxiliary Overvoltage 1 Pickup
7FA3
Auxiliary Overvoltage 1 Pickup Delay
7FA4
Auxiliary Overvoltage 1 Reset Delay
7FA5
Auxiliary Overvoltage 1 Block
7FA7
Auxiliary Overvoltage 1 Target
7FA8
Auxiliary Overvoltage 1 Events
7FA9
Reserved (8 items)
Frequency (Read Only)
8000
Tracking Frequency
Temp Monitor Actual Values (Read Only Non-Volatile)
81C0
Reserved Register T1
81C1
Reserved Register T2
81C2
Reserved Register T3
GE Multilin
RANGE
0 to 655.35
-359.9 to 0
0 to 655.35
-359.9 to 0
0 to 655.35
-359.9 to 0
0 to 655.35
-359.9 to 0
0 to 655.35
-359.9 to 0
0 to 655.35
-359.9 to 0
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 3
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 600
0 to 1
0 to 3
0 to 4294967295
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 4294967295
0 to 2
0 to 1
0 to 65535
2 to 90
-55 to 125
-55 to 125
-2147483647 to
2147483647
D30 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
ohm
0.01
F001
degrees
0.1
F002
ohm
---
F001
degrees
0.1
F002
ohm
0.01
F001
degree
0.1
F002
ohm
0.01
F001
degree
0.1
F002
ohm
0.01
F001
degree
0.1
F002
ohm
0.01
F001
degree
0.1
F002
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F116
0 (Definite Time)
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
---
1
F111
0 (Definite Time)
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
Hz
0.01
F001
C
1
F002
C
1
F002
---
1
F004
DEFAULT
0
0
0
0
B
0
0
0
0
0
0
0
0
0 (Disabled)
0 (SRC 1)
300
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
700
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
300
100
100
0
0 (Self-reset)
0 (Disabled)
0
0
-55
125
0
B-45

Advertisement

Table of Contents
loading

Table of Contents