GE D30 Instruction Manual page 537

Line distance protection system, ur series
Hide thumbs Also See for D30:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 31 of 62)
ADDR
REGISTER NAME
65CE
Power Swing Detect Delay 3 Pickup
65CF
Power Swing Detect Delay 4 Pickup
65D0
Power Swing Detect Seal In Delay
65D1
Power Swing Detect Trip Mode
65D2
Power Swing Detect Block
65D4
Power Swing Detect Target
65D5
Power Swing Detect Event
65D6
Power Swing Detect Shape
65D7
Power Swing Detect Quad Forward Middle
65D8
Power Swing Detect Quad Forward Outer
65D9
Power Swing Detect Quad Reverse Middle
65DA
Power Swing Detect Quad Reverse Outer
65DB
Power Swing Detect Outer Right Blinder
65DC
Power Swing Detect Outer Left Blinder
65DD
Power Swing Detect Middle Right Blinder
65DE
Power Swing Detect Middle Left Blinder
65DF
Power Swing Detect Inner Right Blinder
65E0
Power Swing Detect Inner Left Blinder
65E1
Power Swing I2 Supervision Enable
65E3
Power Swing I2 Supervision
Load Encroachment (Read/Write Grouped Setting)
66C0
Load Encroachment Function
66C1
Load Encroachment Source
66C2
Load Encroachment Minimum Voltage
66C3
Load Encroachment Reach
66C4
Load Encroachment Angle
66C5
Load Encroachment Pickup Delay
66C6
Load Encroachment Reset Delay
66C7
Load Encroachment Block
66C9
Load Encroachment Target
66CA
Load Encroachment Events
66CB
Reserved (6 items)
Phase Undervoltage (Read/Write Grouped Setting) (3 modules)
7000
Phase Undervoltage 1 Function
7001
Phase Undervoltage 1 Signal Source
7002
Phase Undervoltage 1 Pickup
7003
Phase Undervoltage 1 Curve
7004
Phase Undervoltage 1 Delay
7005
Phase Undervoltage 1 Minimum Voltage
7006
Phase Undervoltage 1 Block
7008
Phase Undervoltage 1 Target
7009
Phase Undervoltage 1 Events
700A
Phase Undervoltage 1 Measurement Mode
700B
Reserved (6 items)
7011
...Repeated for Phase Undervoltage 2
7022
...Repeated for Phase Undervoltage 3
Phase Overvoltage (Read/Write Grouped Setting) (3 modules)
7040
Phase Overvoltage 1 Function
7041
Phase Overvoltage 1 Source
7042
Phase Overvoltage 1 Pickup
7043
Phase Overvoltage 1 Delay
7044
Phase Overvoltage 1 Reset Delay
7045
Phase Overvoltage 1 Block
GE Multilin
RANGE
0 to 65.535
0 to 65.535
0 to 65.535
0 to 1
0 to 4294967295
0 to 2
0 to 1
0 to 1
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0.1 to 500
0 to 4294967295
0.05 to 30
0 to 1
0 to 5
0 to 3
0.02 to 250
5 to 50
0 to 65.535
0 to 65.535
0 to 4294967295
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 1
0 to 600
0 to 3
0 to 4294967295
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 4294967295
D30 Line Distance Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F514
---
1
F300
---
1
F109
---
1
F102
---
1
F085
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
ohms
0.01
F001
---
1
F300
pu
0.001
F001
---
1
F102
---
1
F167
pu
0.001
F001
ohms
0.01
F001
degrees
1
F001
s
0.001
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F111
0 (Definite Time)
s
0.01
F001
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F186
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
DEFAULT
9
17
400
0 (Delayed)
0
B
0 (Self-reset)
0 (Disabled)
0 (Mho Shape)
6000
7000
6000
7000
10000
10000
10000
10000
10000
10000
0
200
0 (Disabled)
0 (SRC 1)
250
100
30
0
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
100
100
0
0 (Self-reset)
0 (Disabled)
0 (Phase to
Ground)
0
0 (Disabled)
0 (SRC 1)
1000
100
100
0
B-39

Advertisement

Table of Contents
loading

Table of Contents