Installation
DANGER!
If you unplug the mains cable of the group 2 (B) power supply unit, the
OpenCom 510 will still be operational! However, only the modules supplied by the
group 1 (A) power supply unit, i.e. the central control module and the interface
cards in slots 1 - 6, will be functional.
If you unplug the mains cable of the group 1 (A) power supply unit, the
OpenCom 510 ceases to be operational. However, slots 7 - 12 (D) will still be sup-
plied with operating voltage. (Refer to the illustration OpenCom 510: 1-12 frame
slots on page 27 to determine the location of the modules specified in parentheses
above.)
The LEDs of each module indicate whether the respective module is operational.
For further information on LED indicators, refer to Modules starting on page 59.

4.4.3 Installing the Central Control Module

The OpenCom 510 comes with the central control module installed. Should you
need to exchange the central control module, proceed as follows:
1. Shut down the OpenCom 510. To do so, first restart the system by
– entering the code procedure
telephone, or
– clicking on Restart in the SYS Configuration: Restart menu in the Configu-
rator.
2. Wait until the LEDs of the installed modules start flashing red.
DANGER!
3. Unplug all of the mains cables of the OpenCom 510 to disconnect the system
from the mains supply.
Always unplug the mains cables of both power supply
units when installing the central control module or a
power supply unit.