Table 3.
Exceeding up to
max. 160 °C
(320 °F)
1
2
3
4
5
6
7
Table 4.
Exceeding over
160 °C (320 °F)
1
2
3
4
5
6
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Excess temperature up to max. 160 °C (320 °F) max. 15 min.
Step
The whole oil system must be inspected, repaired or overhauled in accor-
dance with the BRP-Powertrain instructions for continued airworthiness.
Inspect oil level in the oil tank.
Inspect oil cooler for contamination and check the entire oil circuit for correct
functioning.
Check that oil lines are routed correctly and undamaged.
Cut oil filter housing and inspect filter mat for foreign matter.
Carry out oil change.
Inspect all further systems for correct functioning.
Excess temperature over 160 °C (320 °F) for longer than 15 min.
Step
The whole engine must be inspected, repaired or overhauled in accordance
with the BRP-Powertrain instructions for continued airworthiness.
Inspect all further systems for correct functioning.
Carry out detailed inspection of the affected engine components.
The whole oil system (oil cooler, oil lines) must be inspected.
Cut oil filter housing and inspect filter mat for foreign matter.
Carry out oil change.