Points of Inspection
Verify oil level, replenish as necessary.
On configurations with auxiliary generator, check the
attachment and the V-belt tension.
Check the electric fuel pump.
Inspect the fuel system for leaks.
Inspect the fuel system for damages.
Observe the safety instructions!
Start the engine and run to operating temperature.
Limits see Operators Manual 912 i Series.
Ignition check at _____ rpm engine speed.
Speed drop without LANE:
A (Off)___________rpm
B (Off)___________rpm
A/B (difference)________rpm
After engine test run, re-tighten the oil filter by hand
(only at cold engine).
Checks for leaks.
All Service Bulletins are complied with.
Effectivity: 912 i Series
Edition 1/Rev. 0
BRP-Powertrain
MAINTENANCE MANUAL
Interval
Operating hours
as
indicated
18.) Oil level check
19.) Checking the V-belt tension
20.) Electric fuel pump
every 1000 hr.
21.) Fuel system
22.) Engine test run
General note
Chapter
Signature
Reference
100 hr.
X
12-10-00
sec. 4.1)
X
12-20-00
sec. 8)
12-20-00
sec. 11.5)
X
12-20-00
sec. 12.2)
X
X
12-20-00
sec. 7)
X
05-20-00