INSTALLATION OF AN AIR CONDITIONING UNIT

The MAX Caddy wood furnace has been tested with an optional air conditioning unit. If this option is chosen, we
recommend an installation as per the graphic provided below. This installation will provide the most efficient and
safe operation of the air conditioning unit using the distribution blower of the MAX Caddy furnace during summer. In
order to complete the installation of an air conditioning unit, the main thermostat must be a "heat/cool" type.
Furthermore, the PC board of the furnace must be in a COOL mode and the desired distribution blower speed must
be programmed (see MODES section for complete instructions). It must be noted that upon thermostatic demand
for cooling, the distribution blower will start immediately.
The capacity and characteristics of the air conditioning unit that has been tested with the MAX Caddy are stated
below. The use of another brand with similar capacity and characteristics is adequate.
Condenser brand: Goodman GSX13048
Capacity: 4 ton
Coil type: Type A, CAUF uncased indoor coil.
A/C coil
3.16
OIL BURNER INSTALLATION – WOOD-OIL MAX CADDY (OPTIONAL)
Refer to section B for the installation and operation instructions for the UH-MAX CADDY wood/oil combination
furnace.
Damper
Recommended Installation