Installation Of An Air Conditioning Unit - PSG CADDY ALTERNA Installation And Operating Instructions Manual

Pellet furnace
Hide thumbs Also See for CADDY ALTERNA:
Table of Contents

Advertisement

INSTALLATION OF AN AIR CONDITIONING UNIT

The Caddy Alterna pellet furnace has been tested with an optional air conditioning unit. If this option is chosen, we
recommend an installation as per the graphic provided below. This installation will provide the most efficient and
safe operation of the air conditioning unit using the distribution blower of the Caddy Alterna furnace during summer.
In order to complete the installation of an air conditioning unit, the main thermostat must be a "heat/cool" type.
Furthermore, the PC board #2 of the furnace must be in a COOL mode and the desired distribution blower speed
must be programmed (see MODES section for complete instructions). It must be noted that upon thermostatic
demand for cooling, the distribution blower will start immediately.
The capacity and characteristics of the air conditioning unit that has been tested for the Caddy Alterna are stated
below. The use of another brand with similar capacity and characteristics is adequate.
Condenser brand: Goodman GSX13036
Capacity: 4 ton
Coil type: Type A, CAUF (uncased indoor coil).
Damper
A/C coil
Damper
Recommended Installation with an AC unit
24

Advertisement

Table of Contents
loading

Table of Contents