Activating The Splashproof Tpu - Klein 5000 SERIES Operation And Maintenance Manual

Hide thumbs Also See for 5000 SERIES:
Table of Contents

Advertisement

5-10
CHAPTER 5 Splashproof TPU
To connect power to the TPU:
If you will be connecting a 115 VAC or 12 VDC power source to the TPU, set
1.
the VOLTAGE SELECT switch inside the TPU to 115V. Refer to the
CAUTIONS stated above. Close and latch the TPU cover.
If you will be connecting a 230 VAC power source to the TPU, set the
VOLTAGE SELECT switch inside the TPU to 230V. Refer to the CAUTIONS
stated above. Close and latch the TPU cover.
2. Connect the AC power to the 120/230 VAC connector on the TPU.
3. Connect the DC power source to the 12 VDC connector.
5.3

Activating the Splashproof TPU

Activating the Splashproof TPU is similar to that of the rack mount TPU.
electronics, or both.
temperature climates, protect the towfish from direct exposure to the sun prior to and
during operation.
To activate the Splashproof TPU:
Connect the towfish cable to the TOWFISH connector of the TPU.
1.
2. Turn on the computer and wait for it to fully boot up.
3. Switch the RUN/STAND BY switch to STAND BY.
4. Switch the VAC/12 VDC switch to VAC to apply AC power to the TPU; switch to
12 VDC to apply DC power. Refer to the CAUTIONS on page 5-9.
Series 5000 Sonar System Operations and Maintenance Manual
SHOCK HAZARD Do not connect or disconnect the tow cable from the
towfish or the TPU when power is on. Failure to follow this practice may
result in personal injury and will damage the towfish or the TPU
CAUTION Serious damage to the towfish electronics may occur if the
towfish is operated on deck for periods longer than fifteen minutes.
Between periods of operation, let the sonar cool for fifteen minutes. In high
NOTE It is normal for a spark to occur when connecting the DC power
cable to a battery, as the inverter is being powered up.
P/N 11210060, Rev. 16