Klein 5000 SERIES Operation And Maintenance Manual page 141

Hide thumbs Also See for 5000 SERIES:
Table of Contents

Advertisement

$ML2
$ML2
$MG1
$MG1
$MG1
$MG1
System Ready...
NOTE: GPS set to /tyCo/3 at 4800 baud.
An improper boot will hang the system and you may have to configure the TPU.
After a time out period, you will be put into the edit mode for the TPU. You will
now be able to edit the boot parameters. Enter c to change parameters.
Type the new parameter after the current parameter. If there are any other
parameters not noted below, leave them as they are. Entering "?" will give you a
help menu and entering "any key" before the boot sequence will put you in the edit
mode.
boot device
: fei...Leave as is
processor number: : 0...Leave as is
host name
: sonarclient...Name of your host PC as noted earlier
file name
: \klein\vxWorks...Path to vxWorks on your computer
inet on ethernet (e) : 192.168.0.81...Address you give the TPU
host inet (h)
: 192.168.0.82
user (u)
: klein..User name as set up earlier
ftp password (pw)
: klein..User password as set up earlier
flags (f)
: 0x0...Sets boot delay to 10
target name (tn)
: VxTarget...Set as is
startup script (s)
: \klein\startup.ini...Location of startup.ini file
Turn the TPU off and then back on or press the RST button on the CPU inside the
TPU and watch the boot sequence again.
The Klein startup.ini file is used to set boot parameters. The following is a typical
.ini file.
set SONARTYPE 5000
set BATHY 0
set OLDHEADERTYPE 0
set OLDMUX 0
set LASER 0
set RESMODE 0
set BAUDRATE 4800
set STANDBYMODE 0
set DESPECKLESWITCH 0
set SPEEDFILTERSWITCH 1
set TVGPAGE 7
TPU LAN Configuration Setup
D-27