D.11 Problem Troubleshooting - Klein 5000 SERIES Operation And Maintenance Manual

Hide thumbs Also See for 5000 SERIES:
Table of Contents

Advertisement

6. Strip fiber every 1/8 inch until you have stripped 1 inch off (yellow handled
strippers).
7. Clean stripped fiber with an alcohol wipe.
8. Take the connector and fill barrel with epoxy until a blue dot appears on the end
of the ceramic part of the connector. Withdraw the syringe and fill the barrel.
9. Feed the fiber into the barrel by twisting the fiber in the rotational axis until the
fiber seats and some of the fiber comes out of the ceramic connector end.
10. Carefully insert the fiber connector into the oven with a pair of needle nose pliers.
Do not touch the side of the oven with the fiber. It will break.
11. Cook for 10 minutes.
12. When cured, cut the protruding fiber end off using the sapphire pencil tool. Use a
light slicing motion.
13. Polish the tip of the ceramic connector with the pink polishing pad. Polish until
all epoxy has been removed. Use a figure 8 pattern. If there is epoxy on the side
of the barrel, remove it completely with this pad.
14. Place some slurry onto the rubber mat, glass, purple diamond polishing pad.
15. Place the connector into the stainless steel polishing puck. Use a figure 8
polishing stroke.
16. Inspect with the inspection tool, and test for db loss.

D.11 Problem Troubleshooting

The system does not operate, but the LOCK LOSS and ERROR lights are off.
Check the following:
• Hub
• LAN cables
• Path and location path to vxWorks.
• Network setup on the computer and TPU.
The TPU is not functioning properly for no apparent reason. Do the following:
• Check for proper AC voltage setting.
• Check AC fuses.
• Replace boards one at a time.
Problem Troubleshooting
D-55

Advertisement

Table of Contents
loading