3 Components and Power Supply
Configuration parsed
Initializing
Press any key to get started
Once the MiniPoE card has been installed, we can connect the PoE source to the device:
Connecting the PoE source to the device through external PoE adapter connector
Fig. 20:
3.6 RST Button
The different RST button features are described below.
RST button
Fig. 21:
3.6.1 Rebooting the device
Once the device is operating normally, pressing the RST button will make it restart.
3.6.2 Default Configuration
The RST button allows you to boot the device with its default configuration through the following steps:
• With the device switched off, press and hold the RST button down while you turn on the router using the ON/OFF
switch (1).
• The PSU LED (green) will light up and LED 'S' will begin to blink (amber). It will carry on blinking for 10 seconds.
• To boot the device with the default configuration, let go of the RST button while LED 'S' is still blinking (i.e. before
the 10-second period expires).
The router's default configuration establishes the following access IP and mask address:
• IP address: 192.168.1.1
• IP mask: 255.255.255.0
Note
Some devices leave the factory with customized settings. This personalization can mean your router's
default configuration is different from the one shown above.
3.7 Connecting the data
The Teldat iM8 router has the following data connections.