Reset To Factory Settings - Leica 3D Disto User Manual

Hide thumbs Also See for Leica 3D Disto:
Table of Contents

Advertisement

Adjustment step-
by-step
8.5
Reset to factory
settings step-by-
step
1.800.561.8187
3D Disto, Check & Adjust
Step
Description
1.
Set up the 3D Disto close to a wall with a steep target of good visibility that
is at least 15 m above the instrument.
3D Disto_051
2.
Calibration is started in Menu » Device » Calibration.
3.
Press
.
Pointfinder opens
4.
Target as precisely as possible.
5.
Press
.
3D Disto turns to second face automatically.
6.
Target a second time. Press
7.
If both measurements were successful, a pop-up window appears with Set
new: XXX gon, Reset to factory default, or Cancel calibration.
8.
Choose Set... or Reset... to adjust V-index.
9.
Final pop-up asks Are you sure? Yes/Cancel. If Yes, checkmark is displayed
to confirm parameters were set successfully.

Reset to Factory Settings

Step
Description
1.
Calibration is started in Menu » Device » Calibration.
2.
Press
.
Pop-up appears Reset all calibration settings to factory default? Yes/No.
3.
If Yes: all user-defined calibration settings are reset to factory default
without further request.