Leica 3D Disto User Manual page 42

Hide thumbs Also See for Leica 3D Disto:
Table of Contents

Advertisement

1.800.561.8187
3D Disto, Software Applications
Step
Description
Vertical Line Scan:
• Up (360°)
• Point-to point
• Down (360°)
Slope Scan:
Pointfinder opens.
Target scan end and press
Pop-up window prompts to define spacing of the measurement.
6.
Choose an interval and press OK or go to the rightmost position to enter indi-
vidual intervals.
For best scan results do not choose small intervals at long distances.
7.
Press OK.
Scan starts.
Toolbar changes.
Press
to start the camera. Press again to unlock.
Press
to change scan spacing, skip the rest of the scan, continue scan, or
cancel scan.
Press
to skip a scan point that you do not need or that causes problems.
8.
If scan is finished pop-up prompts Ready. Edit Scan? Yes/No.
9.
If Yes: New Toolbar appears, e.g. to measure missing points with DIST or
delete unneeded points with Trash key Symbol.
Press
or
Press
to start a scan simplification that automatically clears aligned
points.
Press
to finish the scan.
www.
.
to select points.
.com
information@itm.com