Replacement Modules - GE B30 Instruction Manual

Bus differential system, ur series
Hide thumbs Also See for B30:
Table of Contents

Advertisement

2 PRODUCT DESCRIPTION
The order codes for the reduced size vertical mount units with the process bus module are shown below.
Table 2–6: B30 ORDER CODES (REDUCED SIZE VERTICAL UNITS WITH PROCESS BUS)
B30
-
*
**
- *
*
* - F
BASE UNIT
B30
|
|
|
|
|
CPU
E
|
|
|
|
J
|
|
|
|
K
|
|
|
|
N
|
|
|
|
SOFTWARE
00
|
|
|
01
|
|
|
(IEC 61850 options not
03
|
|
|
available with type E CPUs)
04
|
|
|
MOUNT/COATING
V
|
|
B
|
|
FACEPLATE/ DISPLAY
F
|
D
|
R
|
A
|
K
|
M
|
Q
|
U
|
L
|
N
|
T
|
V
|
POWER SUPPLY
H
L
CT/VT MODULES
DIGITAL INPUTS/OUTPUTS
7INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
Replacement modules can be ordered separately as shown below. When ordering a replacement CPU module or face-
plate, please provide the serial number of your existing unit.
Not all replacement modules may be applicable to the B30 relay. Only the modules specified in the order codes are
available as replacement modules.
NOTE
Replacement module codes are subject to change without notice. See the web page for the product for the latest
ordering options.
GE Multilin
**
- H
**
- L
**
- N
**
- R
**
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
81
|
|
|
XX
XX
XX
|
4A
|
4B
|
4C
|
4D
|
4L
|
67
|
6A
|
6B
|
6C
|
6D
|
6E
|
6F
|
6G
|
6H
|
6K
|
6L
|
6M
|
6N
|
6P
|
6R
|
6S
|
6T
|
6U
|
6V
|
2A
2B
2E
2F
2G
2H
72
73
74
75
76
77
7A
7B
7C
7D
7E
7F
7G
7H
7I
7J
7K
7L
7M
7N
7P
7Q
7R
7S
7T
7W
B30 Bus Differential System
Reduced Size Vertical Mount
Base Unit
RS485 and RS485
RS485, multi-mode ST 100Base-FX, and 10/100Base-T
RS485, multi-mode ST redundant 100Base-FX, and 10/100Base-T
RS485 and 10/100Base-T
No software options
Ethernet Global Data (EGD) protocol
IEC 61850 protocol
IEC 61850 and Ethernet Global Data (EGD) protocols
Vertical (3/4 rack)
Vertical (3/4 rack) with harsh environmental coating
English display
French display
Russian display
Chinese display
Enhanced front panel with English display
Enhanced front panel with French display
Enhanced front panel with Russian display
Enhanced front panel with Chinese display
Enhanced front panel with English display and user-programmable pushbuttons
Enhanced front panel with French display and user-programmable pushbuttons
Enhanced front panel with Russian display and user-programmable pushbuttons
Enhanced front panel with Chinese display and user-programmable pushbuttons
125 / 250 V AC/DC power supply
24 to 48 V (DC only) power supply
Eight-port digital process bus module
No Module
4 Solid-State (no monitoring) MOSFET outputs
4 Solid-State (voltage with optional current) MOSFET outputs
4 Solid-State (current with optional voltage) MOSFET outputs
16 digital inputs with Auto-Burnishing
14 Form-A (no monitoring) Latching outputs
8 Form-A (no monitoring) outputs
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 digital inputs
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 digital inputs
8 Form-C outputs
16 digital inputs
4 Form-C outputs, 8 digital inputs
8 Fast Form-C outputs
4 Form-A (voltage with optional current) outputs, 8 digital inputs
6 Form-A (voltage with optional current) outputs, 4 digital inputs
4 Form-C and 4 Fast Form-C outputs
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 digital inputs
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 digital inputs
4 Form-A (current with optional voltage) outputs, 8 digital inputs
6 Form-A (current with optional voltage) outputs, 4 digital inputs
2 Form-A (no monitoring) and 2 Form-C outputs, 8 digital inputs
2 Form-A (no monitoring) and 4 Form-C outputs, 4 digital inputs
4 Form-A (no monitoring) outputs, 8 digital inputs
6 Form-A (no monitoring) outputs, 4 digital inputs
2 Form-A outputs, 1 Form-C output, 1 Form-A latching output, 8 digital inputs
C37.94SM, 1300nm single-mode, ELED, 1 channel single-mode
C37.94SM, 1300nm single-mode, ELED, 2 channel single-mode
Bi-phase, single channel
Bi-phase, dual channel
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
1550 nm, single-mode, LASER, 1 Channel
1550 nm, single-mode, LASER, 2 Channel
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, LASER
Channel 1 - G.703; Channel 2 - 1550 nm, Single-mode LASER
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
820 nm, multi-mode, LED, 1 Channel
1300 nm, multi-mode, LED, 1 Channel
1300 nm, single-mode, ELED, 1 Channel
1300 nm, single-mode, LASER, 1 Channel
Channel 1 - G.703; Channel 2 - 820 nm, multi-mode
Channel 1 - G.703; Channel 2 - 1300 nm, multi-mode
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
820 nm, multi-mode, LED, 2 Channels
1300 nm, multi-mode, LED, 2 Channels
1300 nm, single-mode, ELED, 2 Channels
1300 nm, single-mode, LASER, 2 Channels
Channel 1 - RS422; Channel 2 - 820 nm, multi-mode, LED
Channel 1 - RS422; Channel 2 - 1300 nm, multi-mode, LED
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, LASER
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode LASER
G.703, 1 Channel
G.703, 2 Channels
RS422, 1 Channel
RS422, 2 Channels

2.1.3 REPLACEMENT MODULES

2.1 INTRODUCTION
2
2-7

Advertisement

Table of Contents
loading

Table of Contents