5 SETTINGS
The B30 is provided with this optional feature, specified as an option at the time of ordering. Using the
order code for your device, see the order codes in chapter 2 for details.
User-programmable pushbuttons provide an easy and error-free method of entering digital state (on, off) information. The
number depends on the front panel ordered.
Enhanced horizontal front panel — 16 user-programmable pushbuttons
Enhanced vertical front panel — 6 user-programmable pushbuttons
Standard horizontal front panel — 12 user-programmable pushbuttons
User-programmable pushbuttons require a front panel with that option. If the front panel was ordered separately,
update the EnerVista software under Maintenance > Enable Pushbutton.
NOTE
The digital state can be entered locally (by directly pressing the front panel pushbutton) or remotely (via FlexLogic oper-
ands) into FlexLogic equations, protection elements, and control elements. Typical applications include breaker control,
autorecloser blocking, and setting groups changes. The user-programmable pushbuttons are under the control level of
password protection.
The figure shows user-configurable pushbuttons for the enhanced front panel.
USER
USER
USER
USER
LABEL 1
LABEL 2
LABEL 3
LABEL 4
Figure 5–7: USER-PROGRAMMABLE PUSHBUTTONS (ENHANCED FRONT PANEL
The following figure shows user-configurable pushbuttons for the standard front panel.
1
USER LABEL
2
USER LABEL
Figure 5–8: USER-PROGRAMMABLE PUSHBUTTONS (STANDARD FRONT PANEL
Both the standard and enhanced front panel pushbuttons can be custom labeled with a factory-provided template, available
online at http://www.gegridsolutions.com/multilin. The EnerVista software can also be used to create labels for the
enhanced front panel.
Each pushbutton asserts its own "On" and "Off" FlexLogic operands (for example,
). These operands are available for each pushbutton and are used to program specific actions. If any pushbutton is
OFF
active, the
operand is asserted.
ANY PB ON
Each pushbutton has an associated LED indicator. By default, this indicator displays the present status of the correspond-
ing pushbutton (on or off). However, each LED indicator can be assigned to any FlexLogic operand through the
setting.
LED CTL
The activation and deactivation of user-programmable pushbuttons depends on whether latched or self-reset mode is pro-
grammed.
Latched mode: In latched mode, a pushbutton can be set (activated) by asserting the operand assigned to the
setting or by directly pressing the associated front panel pushbutton. The state of each pushbutton is stored
BTN 1 SET
in non-volatile memory and maintained through a loss of control power.
GE Multilin
USER
USER
USER
USER
LABEL 5
LABEL 6
LABEL 7
LABEL 8
3
5
USER LABEL
USER LABEL
4
6
USER LABEL
USER LABEL
B30 Bus Differential System
USER
USER
USER
USER
LABEL 9
LABEL 10
LABEL 11
LABEL 12
7
9
USER LABEL
USER LABEL
8
10
USER LABEL
USER LABEL
PUSHBUTTON 1 ON
5.2 PRODUCT SETUP
USER
USER
USER
USER
LABEL 13
LABEL 14
LABEL 15
LABEL 16
842814A1.CDR
11
USER LABEL
12
USER LABEL
842779A1.CDR
and
PUSHBUTTON 1
PUSHBTN 1
PUSH-
5-47